Disconnect the torch components
1.
Remove the 6-wire connector from the receptacle on the RF torch PCB. Do not pull the wires.
Refer to
on page 66 for location.
2.
Remove the wires from the 2-pin receptacles on the RF torch PCB. One wire at a time, push the
lever on the 2-pin wire receptacle while you pull the wire straight out of the receptacle. It can be
necessary to use some force, or push the wire into the receptacle before you pull it out. Refer to
a.
Remove the blue and black cap-sensor switch wires from the receptacle.
b.
Remove the 2 red RF wires from the receptacle.
3.
One wire at a time, remove the blue and black torch-lock switch wires from the notch in the RF
torch PCB. Then pull the torch-lock switch connector out of the receptacle. Use your fingernails
to pull out the connector. Do not pull the wires. Refer to
Figure 10
– RF torch PCB connections for full-length machine torch
4.
Put the RF torch PCB in an anti-static container, unless you are replacing the RF torch PCB.
5
1
2
3
4
6
6
1
6-wire connector
2
2-pin wire receptacle
3
Blue and black cap-sensor switch wires
4
Red RF wires
5
Notch in the RF torch PCB
6
Torch-lock switch connector
Summary of Contents for SmartSYNC 059719
Page 1: ...SmartSYNC Torches Service Parts and Procedures Guide 810460 REVISION 0 ENGLISH ...
Page 10: ...10 810460 Service Parts and Procedures SmartSYNC ...
Page 12: ...Before You Begin 1 12 810460 Service Parts and Procedures SmartSYNC ...
Page 42: ...Prepare to Do the Part Replacement 3 42 810460 Service Parts and Procedures SmartSYNC ...
Page 62: ...Hand Torch Part Replacement Procedures 4 62 810460 Service Parts and Procedures SmartSYNC ...
Page 96: ...Torch Lead Replacement Procedures 7 96 810460 Service Parts and Procedures SmartSYNC ...
Page 98: ...Do a Check of the Torch Assembly 8 98 810460 Service Parts and Procedures SmartSYNC ...