Hand Torch Part Replacement Procedures
4
56
810460
Service Parts and Procedures
SmartSYNC
13.
Put the RF wire through the routing post and into the slot in the RF wire clip.
14.
Put the trigger spring on the mounting stud in the trigger.
15.
Fully compress the trigger spring. Keep the trigger spring compressed as you push the trigger
assembly into the torch handle. Do not let the trigger spring eject from the torch handle.
1
2
3
4
1
2
3
4
75° hand torch
15° hand torch
1
RF wire
2
RF wire clip
3
2 mounting studs
4
Routing post
1
2
3
1
Trigger spring
2
Mounting stud
3
Trigger assembly