Hand Torch Part Replacement Procedures
4
52
810460
Service Parts and Procedures
SmartSYNC
6.
Push the start-switch wire connector into the start switch until you hear a click.
Install the torch components into the torch handle
1.
Put the cap-sensor switch onto the cap-sensor mounting stud in the right side of the torch
handle.
75° hand torch
15° hand torch
NOTICE
Keep the cap-sensor switch flat in relation to the torch handle, especially with the 15° torch. The fit is
tight, and you can break the cap-sensor switch if you use force.