4
Sensor OHC Operation and Set Up Guide
Description and Features
System Features*
Compatible Motors
DC permanent magnet 24VDC, 2 Amps to 6 Amps
(customer supplied)
Max Power Output
150W
Control Range
Linear 0.1” (2.5mm ) to 1.0” (25mm)
Motor Output
Full “H” bridge PWM with current sensing
Accuracy
.01” (.25mm )**
Operator controls
Easy to use control set point knob and easy read indicators
Calibration
Easy access calibration pot on front Panel
Measuring Technology
Capacitive Ring with Coax Cable
Dimensions
8.50” (216mm ) W x 4.21” (107mm) D x 4.02” (102mm) H
Inputs/ Outputs
3 outputs and 6 inputs optically isolated on “D” connectors
Weight 2.4
lbs
Operating Environment
0 to 50C; 95% relative humidity (non-condensing)
Power
24VAC +/- 10% 50/60 Hz
*Information subject to change without notice.
** Dependent on customer supplied lifter mechanics
SENSOR™ OHC - Oxy Height Control is an advanced automated height control system for
oxy fuel shape cutting applications. This product utilizes advanced capacitive sensing and
microprocessor technology to automatically detect the plate and adjust torch position to a
desired set point during oxy fuel cutting operations. This reduces operator input, improves
accuracy and increases productivity.
Features
¾
Sensor OHC can be used with any CNC
¾
Easy setup & operation
¾
Both manual & automatic operation modes
¾
Microprocessor control for increased sensitivity and control
¾
High positioning speeds possible with up to 6 amps continuous current and linear
adjustment over full range
¾
Built-in diagnostic and fault detection features
¾
Auto retract on plate contact
¾
Optional second height set point input for preheat or pierce
¾
Indicator lights for operation including:
⇒
Power
On
⇒
Upper Limit Switch
⇒
Lower Limit Switch
Options
¾
Five Cable Lengths from 19.7” (500mm) to 59” (1500mm)
¾
Adapter cables allowing direct replacement for existing AR-300/100W Levilator Clearance
Controls
⇒
In Position Indicator
⇒
Attention / Error indicator
Summary of Contents for SENSOR OHC
Page 4: ......
Page 6: ...2 Sensor OHC Operation and Set Up Guide ...
Page 24: ...20 Sensor OHC Operation and Set Up Guide Connector Kit CONN 141 Components ...
Page 25: ......
Page 26: ...Printed in the USA MANU 0044 ...