600V INSTALLATION
2-10
600V Installation Manual
1.
Connect L1 (Black), L2 (White) and L3 (Red) of the three-phase transformer secondary
power cord to TB1 of the link box as shown in Figure 2-8.
2.
Connect the ground (Green) wire to the stud marked above the terminal block .
HOOKING UP THE THREE-PHASE TRANSFORMER SECONDARY
POWER CORD FROM 600V TRANSFORMER CASE ASSEMBLY TO
POWERMAX900
WARNING
BE CERTAIN THAT WIRES ARE CONNECTED EXACTLY AS SHOWN ABOVE. AS A
PRECAUTION, CHECK CONTINUITY FROM POWER SUPPLY ENCLOSURE TO INCOMING
GROUND WIRE BEFORE CONNECTING TO POWER.
TB1
Link Box
Conductor
Color
L1
Black
L2
White
L3
Red
Ground
Green
White
Black
Red
Green
Figure 2-8 Connecting the Transformer Secondary Power Cord
from 600V Transformer Case to Powermax900
3.
Connect the rear panel to the Powermax900 power supply and secure with screws.
4.
Tighten the strain relief screws around the power cord. Be certain that the strain relief
grips the outer insulation of the power cord and not the individual wires. See completed
assembly in Figure 2-1.