Powermax30 AIR
Service Manual
808850
71
5 – Troubleshooting and System Tests
Control board LEDs
The control board (PCB1) is located inside of the front panel.
Figure 3
The control board has four diagnostic LEDs:
Reset
– This LED illuminates when certain voltage readings to the power board are out of range. See
Error
– This LED illuminates when the internal compressor, torch cap, or temperature LEDs on the front of the power
supply illuminate. If all four LEDs on the front of the power supply are blinking, the Error LED also blinks. The number
of blinks between pauses indicates which component may have failed.
Transfer
– This LED illuminates when there is proper arc transfer between the torch and the workpiece, and blinks
during continuous pilot arc operation (such as when cutting expanded metal or moving the arc off the plate and then
back on).
Start
– This LED illuminates when the power supply receives a start signal and remains illuminated during normal
operation.
Control board
Ribbon cable