Prepare to Troubleshoot Internal Components
2
28
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
Do an initial resistance check
Make sure that you get all resistance values with the power cord disconnected and all internal
plasma power supply wires correctly attached. Before you do an initial resistance check, do the
steps in
If resistance values are not close (±25%) to the values given in this section, isolate the problem by
removing wires attached to the resistance check points or component until you find the problem.
After you repair the problem, refer to
on page 158 to do a test of the plasma
power supply for correct operation.
Examine the power switch
1.
Set the power switch on the plasma power supply to OFF (
O
), and disconnect the power cord.
2.
Disconnect the torch from the plasma power supply.
3.
Remove the plasma power supply cover and the component barrier.
4.
Set the power switch on the plasma power supply to ON (
I
).
5.
Measure the resistance across the input leads. Refer to
on page 29. The leads have
the labels
L1
,
L2
, and
L3
on the power switch.
CSA and 230 V – 400 V CE models:
The resistance across the input leads =
650 kiloohms (kΩ).
CCC and 400 V CE models:
The resistance across the input leads = 400 kiloohms (kΩ).
Summary of Contents for Powermax105
Page 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Page 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Page 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Page 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...