Access Service Information and Settings
6
156
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
System behavior also changes in the following ways:
The system does not record data on pilot arcs or arc transfers for the cartridge. The system
also does not record some data for the plasma power supply. Refer to
data for the plasma power supply
Cartridge end-of-life detection is disabled when the output current (A) is below 55 A for any
type of Hypertherm cartridge.
The fault LED on the hand torch flashes yellow for as long as the system is in basic mode.
The amperage-adjustment control on the hand torch does not adjust the amperage for as
long as the system is in basic mode.
When the system is in basic mode, the non-default
configuration icon (at right) shows on the status screen
instead of the system process icon.
Set system settings to factory default
To set the plasma power supply to factory default settings, do the following. You can do these steps
on all screens.
1.
Push and hold
and
at the
same time for approximately 2 seconds
until the
FACTORY RESET?
message
shows.
2.
Turn the adjustment knob to go to
, and push
to select it.
The system goes back to factory default
settings, as follows:
The brightness, contrast, and CNC
interface fields go back to their default
settings.
All of the fields on the Feature
Configuration (
FEATURE CONFIG
)
screen go back to their default settings.
The non-default configuration icon (at right) no longer shows on the status
screen.
If you have a Hypertherm cartridge on a SmartSYNC torch, the system
process icon (at right) shows on the status screen.
The system goes back to the factory default settings for the cartridge
installed on the torch. These settings are for output current (A) and operating mode.
Summary of Contents for Powermax105
Page 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Page 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Page 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Page 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...