HyPrecision 50S/60S/75S
Operator Manual
808690
165
7 – Troubleshooting
Tr
oubleshooting
Short seal life
If the high-pressure water seals have a short life, take these actions.
Make sure that the mating surfaces are smooth and free of debris.
Repair or replace the high-pressure cylinder and plunger.
Make sure that the water quality is within satisfactory ranges. Refer to the
section, which
begins on page 188.
Examine the ends of the high-pressure cylinder for cracks.
Replace the high-pressure water seals and hoops.
Check the air pressure in the water accumulator tank. Refer to page 89 for instructions.
Replace the high-pressure cylinder.
If the high-pressure seal backups have a short life, make sure that the plunger bearing is not worn.
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...