HyPrecision15/30/50
Operator
Manual 808240
73
5 – Preventive maintenance
Preventive maintenance
Add hydraulic fluid
The capacity of the hydraulic fluid tank is 151 L (40 gallons).
For air-cooled pumps, increase the hydraulic fluid available by at least 19 liters (5 gallons) to fill the hoses and heat
exchanger.
Required tools, materials, and parts
ISO viscosity grade (VG) 32 or 46 antiwear mineral or synthetic hydraulic fluid
Recommended materials
Clean funnel
Do this task when the pump is not running.
1.
Make sure that the drain valve is closed.
2.
Remove the filler-breather cap on top of the tank.
3.
Fill the tank with hydraulic fluid until the fluid is at the top mark on the sight gauge.
4.
Install the original filler-breather cap.
Do not overfill the hydraulic fluid tank.
1
2
3
1
Drain valve lever
2
Filler-breather cap
3
Sight gauge
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...