O
p
eration
Stop the pump
Emergency stop
The EMERGENCY STOP pushbutton is intended for urgent disabling of the controls. It is not the preferred method of
turning off the pump.
Press the EMERGENCY STOP pushbutton.
The control circuit turns off, which causes the pump, primary motor, and intensifier to turn off.
The bleed-down valve opens and discharges high-pressure water from the system.
The CONTROLS ON button indicator light turns off.
Routine stop during operation
1.
Turn OFF the cutting head.
2.
Press F1 on the operator interface to turn off the primary motor. The bleed-down valve opens and discharges
high-pressure water from the system.
Routine stop at the end of the day
1.
Turn OFF the primary breaker disconnect lever on the electrical enclosure door. The operator interface screen turns
off.
2.
Turn OFF the water to the pump.
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...