Operate the pump remotely
Refer to the remote-source manufacturer’s instructions for operating the pump from a remote source.
If the pump is connected to a remote source and is using the remote CONTROLS ON function, refer to the
remote-source manufacturer’s for an emergency stop reset.
CONTROLS ON
This turns on the controls by turning on the primary control relay. The controls must be turned on
before other commands can be used.
If the pump is off, this turns on the primary control relay.
If the pump is turned off with the EMERGENCY STOP pushbutton or as the result of a fault, the pump
can not be turned on remotely.
EMERGENCY
STOP
The EMERGENCY STOP pushbutton is available on the operation panel and at the remote control
source.
If the pump is running, this turns off the pump.
PUMP ON
This turns on the primary motor, the supply water, the cooling fan, and the fan starter motor. (The
cooling fan is optional for air-cooled pumps.) The intensifier strokes in pierce-pressure mode for a
time that is set at the operator interface. When the timer expires, the intensifier strokes to
cut-pressure mode.
If the pump is in cooling mode, this causes the intensifier to start stroking.
PUMP OFF
This turns off the primary motor and the supply water. In air-cooled pumps, it also turns off the fan
motor starter and the cooling fan.
COOLING ON
If the pump is running, this turns off the intensifier.
If the pump is off, this turns on the primary motor and the cooling water or the cooling fan.
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...