Preventive maintenance
Assemble the bleed-down valve
Required tools, materials, and parts
11328 On/off valve and bleed-down valve repair kit
11743 Bleed-down valve flow reducer
High-pressure antiseize lubricant such as Blue Goop or AccuGoop
1-inch open-ended wrench
3/4-inch open-ended crowfoot wrench or socket
Torque wrench
Cross-tip screwdriver
1.
Put high-pressure antiseize lubricant on the seat.
2.
Put the flow reducer into the outlet adapter.
3.
Put the seat into the outlet adapter.
4.
Install the outlet adapter in the bleed-down valve body. Torque the adapter to 27 N ∙ m (20 lbf ∙ ft).
Use 2 wrenches.
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
1
2
3
1
Outlet adapter
2
Flow reducer
3
Seat
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...