5 – Preventive maintenance
Preventive maintenance
Assemble the intensifier
Install the indicator pin assembly
Refer to the Parts lists section, which begins on page 147, for part numbers and ordering information.
Required tools, materials, and parts
11518 Indicator pin
11669 Indicator pin spring
White lithium grease antiseize bolt lubricant
Hydraulic fluid
Torque wrench
5/32-inch hex wrench or hex-bit socket
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
Review the safety information on page 62.
Put the parts on a clean, dry, oil-free surface.
1
2
3
4
5
6
1
Cap screws and lock washers
2
Indicator pin cap
3
Backup ring
4
O-ring
5
Indicator pin spring
6
Indicator pin
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...