Maintenance
HPR130XD Auto Gas –
806330
5-11
Error code troubleshooting – error codes 000 to 018
Error code
number
Name
Description
corrective action
000
No error
System is ready to run.
None needed.
009
Flow switch
test
The flow switch is tested
when the pump restarts
after a pump timeout
(30 minutes without a
start signal). The test
ensures that the coolant
flow is correct before
firing the torch.
Wait 10 seconds for the flow rate to stabilize.
011
No active
processs
HPR400XD
HPR800XD
only
The current setting is
greater than the capability
of the selected process.
When this error code
occurs, the power supply
will ignore the start signal
until a correct process
is chosen.
Note: To protect against unintended operation after a
system reset, the current will be set to 5 amperes.
If a correct proces is sent, the system will operate
normally.
1. Verify that the secondary power supply is turned ON.
2. Verify that the current for the selected process is within
the range of the power supply capability (up to 400A for
400XD, and up to 800A for 800XD).
012
Test in
progress
One of the gas test
modes is running.
Wait for the test to finish.
013
Test passed The test was successful.
No action required.
014
Cut gas
channel 1 fail
The gas pressure in
channel 1 is decreasing,
which indicates a leak.
Look for leaks and loose connections between the selection
console and the metering console.
015
Cut gas
channel 2 fail
The gas pressure in
channel 2 is decreasing,
which indicates a leak.
Look for leaks and loose connections between the selection
console and the metering console.
016
Plasma
rampdown
fail
Plasma pressure did
not decrease in the time
allowed.
Verify that there is no obstruction in the plasma vent hose.
017
Shield
rampdown
fail
Shield pressure did not
decrease in the time
allowed.
Inspect the holes in the shield for obstructions. Replace the
shield if the holes are blocked.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...