The information provided here is the basic information for connection of the shape cutting control to
the cutting table. Each machine interface will vary slightly based on the cutting table configuration
and features. Additionally, I/O pinout information may vary slightly based on the configuration of the
selected I/O and their locations. Changes to the I/O configuration may be made in the password
protected I/O screen. All controls are shipped with a default selection of Inputs and interface
locations for the selected control Interface (I/O) configuration. Installation and service should only be
performed by a qualified service technician.
The rear panel of the control
has several cable connectors to connect the control to power, I/O and
communication ports. These connectors are clearly labeled as to their function.
AC Input
The AC power cable is inserted into the AC power connector and plugged into a standard 3-way 115
or 230 volt outlet. The AC Power connector contains an integral fuse module and line filter. AC input
power can be selected by the user by changing position of the fuse module so that the selected
voltage is displayed.
WARNING!
Ensure
proper orientation of fuse module for input power before applying power to
the CNC. Component damage could occur with incorrect voltage setting.
Recommended AC Fuses
Different fuse ratings are recommended based on incoming voltage selected.
Voltage Input: 120Vac uses 8 amp (slow blow) Littlefuse part #313008
Voltage Input: 220Vac uses 5 amp (slow blow) Littlefuse part #313005
Size: ¼” x 1¼” or 5mm x 20MM fuse can be used
Serial Port
Please refer to the Ports Information section of the Installation Guide for additional information on
configuration of Serial ports for communication.
A remote communications link can be connected to one of the two serial ports and an external ground
(PE) lug for earth grounding of the unit is also provided.
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......