![Hypertherm Edge TI Manual Download Page 466](http://html1.mh-extra.com/html/hypertherm/edge-ti/edge-ti_manual_2193678466.webp)
Program Codes
442
Message Command Type
>20< This command delays the part program until all bytes have been transmitted, then optionally
waits the Delay Time, if specified.
>21< A message is sent concurrent to execution of the part program and no delay is encountered.
No acknowledge is required.
>22< The message is sent with a suspension of the program during transmission as in option one,
but an Acknowledge from the external device (ACK = Hexadecimal 06 ) is required before
the part program can continue. A Non-Acknowledge (NAK = Hexadecimal 15) response from
the external device will prompt a retransmit of the message from the control.
An optional Time Out value may be added to the program code. If no Time Out code is used
in the program code the Default time out value at the Ports setup screen will be used.
Additionally, an optional automatic retry feature may be enabled at the Ports setup screen.
With the automatic retry feature the message will automatically be retransmitted if no
response is detected. The retry is executed after the Time Out value has elapsed. The
number of retries can be defined on the Ports configuration screen.
Optional Format Value
Specialty characters for the format may be sent in addition to command string.
Specialty Characters Supported
HEX
Name
Description
01
SOH
Start of Header
02
STX
Start of Text
03
ETX
End of Text
04
EOT
End of Transmission
0A
LF
Line Feed
0D
CR
Carriage Return
BCC
“Exclusive Or” Check Byte
Note: Checksum is always an 'Exclusive OR' of the Data ONLY as it does not include any of the
'Format' chars including the CR/LF option.
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......