44
Duramax/Duramax Hyamp Robotic Torches
Service Manual 807460
2 – Torch Setup
Setting the five-position voltage divider
To change the factory preset voltage divider from 50:1 to a different setting:
1.
Turn OFF the power supply and disconnect the power cord.
2.
Remove the power supply cover.
3.
Locate the voltage divider DIP switches on the left side of the power supply.
shows the default setting (50:1) with the number 4 switch up.
Figure 19 – Voltage divider at default setting (50:1)
4.
Set the DIP switches to one of the following settings, and replace the power supply cover.
If the Hypertherm five-position voltage divider does not supply the required voltage for your application, contact your
system integrator for assistance.
20:1
21.1:1
30:1
40:1
50:1
Summary of Contents for Duramax
Page 1: ...Duramax and Duramax Hyamp Robotic Torches 45 90 180 Service Manual 807460 Revision 2 English ...
Page 6: ......
Page 10: ...10 Duramax Duramax Hyamp Robotic Torches Service Manual 807460 Contents ...
Page 20: ...20 Duramax Duramax Hyamp Robotic Torches Service Manual 807460 1 Specifications ...
Page 46: ...46 Duramax Duramax Hyamp Robotic Torches Service Manual 807460 2 Torch Setup ...