background image

Installation & operating instructions

F4 Enterprises Limited

7 Abbey Square, Chester

CH1 2HU,  UK

Tel: +44 (0)1352 736120

www.f4enterprises.co.uk

The Hylite Mightylite fl oodlight a low energy, high powered outdoor LED fl oodlight which is suitable for installation on solid 

walls in a range of locations including entrances, gardens, staircases, garages and outdoor parking areas

The unit requires connection to a 230 AC 50Hz mains electricity supply.  

WARNING: THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN, AND CHECKED TO ENSURE

IT IS SAFE BEFORE USING

 

PLEASE FOLLOW THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS LIGHT 

    The risk of electric shock should be minimized by the installation of appropriate safety devices including the  

 

    incorporation of an RCCB (Residual Current Circuit Breaker) into the main distribution board. 

 

    DO NOT wire this fl oodlight directly into the lighting circuit. Use a switched fused spur. Cables should always be    

    protected against short circuit and overload by use of an RCD.

 

    Ensure the voltage marked on the product is the same as the electrical power supply to be used.

 

    DO NOT install the light where it is likely to be knocked or hit, or in hot or humid conditions such as bathrooms, shower  

    rooms or saunas; or near an exhaust outlet e.g. boiler fl ue, dryer outlet.

 

 

  

    DO NOT position the light near fl ammable or combustible materials (such as cloth or paper) or near fl ammable,  

 

    combustible or explosive liquids, solids, gases or equipment.

 

    DO NOT look directly into the light or point it towards a person’s eyes. This light has a very intensive light output which, if  

    incorrectly used, could cause eye damage.

    ALWAYS disconnect the mains power supply before installing, servicing or performing any maintenance.

    ALWAYS maintain the light in good condition, with repairs only undertaken by a qualifi ed electrician.

    ONLY carry out repairs using genuine parts. Non-authorised parts may be dangerous and will invalidate the warranty.

1. IMPORTANT SAFETY INSTRUCTIONS

HYLITE MIGHTYLITE WITH PIR – INSTALLATION AND OPERATING INSTRUCTIONS

TROUBLESHOOTING

Fig.2

Fig.3

FUSE

3 AMP FUSE

TO LAMP

FROM MAINS

SUPPLY

DOUBLE-POLE SWITCHED FUSED SPUR

F

1

2

5

4

3

T

R

PIR

sensor

More sensitive

Less sensitive

L

N

SL

E

Override switch

Live

C

L1

Neutral Earth

To Mains

MightyLite

N In

N Out

L In

L Out

FUSE

3 AMP FUSE

TO LAMP

FROM MAINS

SUPPLY

DOUBLE-POLE SWITCHED FUSED SPUR

F

1

2

5

4

3

T

R

PIR

sensor

More sensitive

Less sensitive

L

N

SL

E

Override switch

Live

C

L1

Neutral Earth

To Mains

MightyLite

N In

N Out

L In

L Out

3-5m

The PIR detector on the fl oodlight responds to changes in temperature as well as 

movement, therefore please ensure that the following steps are taken in choosing 

a location:

•  Mount the fl oodlight onto solid brick or woodwork, 3 - 5m above the ground  

  [Fig. 2]

•  Avoid positioning the light near heat sources such as hot ventilator ducts,  
  air conditioning units, street lighting or traffi c which may interfere with its  
 operation.

•  Avoid pointing the light towards objects that may move in the wind, such  as  
  trees or shrubs, or highly refl ective surfaces.

•  When positioning the light, note that the PIR sensor is more sensitive to a heat  
  source moving across its coverage area and less sensitive to a heat source that  
  moves directly towards the PIR sensor [Fig.3]. 

3.1 CHOOSING A MOUNTING LOCATION

3. INSTALLATION INSTRUCTIONS

WARNING: Isolate the power supply before installation.

The Mightylite can be fi xed in position by EITHER:

Option 1: Attaching the connection box directly to a wall (or vertical surface) and 

attaching the Mightylite to the connection box , or

Option 2: Attaching the U bracket to the mounting surface and attaching the 

Mightylite to the U bracket.

3.2 FIXING THE MIGHTYLITE

2. WIRING REQUIREMENTS

Fig.1

TO MAINS

MIGHTYLITE

Earth

L in

L out

N in

N out

The unit requires connection to a 230 AC 50Hz mains electricity supply.

It is recommended that the unit is connected to the domestic lighting circuit via a 5 amp 

fused spur and using 2-core round fl exible cable of at least 1mm

2

 gauge (waterproof 

cable should be used for outdoor installations).

It is also advisable to install a single pole wall switch to allow easy control of the 

fl oodlight (Fig. 1).

NOTE: The MightyLite has a switched override facility enabling it to be switched on 

manually, via a second wall switch, without requiring PIR activation. See section 

“Wiring the Floodlight” for wiring details.

TOOLS REQUIRED

Electric/hand-held drill

No.8 masonry drill bit

Electricians screwdriver

Large cross-head screwdriver 

Small cross-head screwdriver 

Wire cutters
THIS PRODUCT IS SUITABLE FOR WALL MOUNTING ONLY.

  

PARTS INCLUDED

 

  1 x Mightylite LED Floodlight with built-in PIR

  1 x Connection box

  1 x Cable gland

  4 x Connection box screws

  4 x Connection box screw covers

  4 x Connection box fi xing screws

  4 x Connection box fi xing screw covers
   

1 X U bracket

   2 x Securing knobs

Mightylite 36W LED Floodlight with built-in PIR
Model: MLF136

1.1 IMPORTANT OPERATION & MAINTENANCE INSTRUCTIONS

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

Lights won’t come 
on

• Power not on

• Wired incorrectly

• PIR not detecting movement

• Light conditions too bright

• Turn on indoor switch or check fuse

• Check wiring is the same as wiring diagram

• Adjust the angle and direction of the PIR. For best   

   results walk across the beam

• Wait until light conditions are darker (at dusk or  

   under 40 Lux) or turn the LUX control up.

Lights stay on

• TIME set too high

• Wired incorrectly

• Frequent changes in heat are being  

   detected

• Switched override ON

• Turn ‘Time’ knob towards ‘-’ end (15 secs to 5 min 

   adjustable)

• Check wiring is the same as wiring diagram.

• Check sensing area for possible heat sources 

   (e.g. air vents, moving vehicles, moving trees) and 

   re-position the sensor or alter the  RANGE control 

   downwards

• Check status of switched override and change if required

Lights keep turning 
on and off (cycling)

• Changes in heat are being detected 

   from a fi xed heat source.

• Changes in heat are being detected 

   from a moving object.

• Light and heat are being refl ected 

   back onto the sensor.

• Sudden temperature changes due to 

   storms or high winds

• Check the sensing area for air vents, light fi ttings or 

   fans and either re-position the sensor or adjust the aim

• Check the sensing area for moving vehicles, animals, 

   pedestrians, moving trees and alter the aim of the 

   sensor accordingly

• Alter aim of the sensor or paint the refl ecting surface 

   with a dull fi nish

• Turn sensor off until storm passes or install in a 

   sheltered location

Sensor operates 
differently in hot and 
cold conditions

• Temperature differences are    

   affecting the sensitivity of the sensor

• Turn the sensitivity (RANGE) control knob toward 

   the MAXIMUM end for summer (hot conditions) and 

   toward MINIMUM for winter (cold conditions). This 

   compensates for variations in temperature.

•  Position the unit on the wall and mark the position for the connection box  
  (which can be positioned in either landscape or portrait planes [Fig. 4].

•  Ensure the wires can easily enter the connection box through either one of the  
  knock-outs on the side of the connection box, or through the knock-out at the  
  rear of the box.

 

NOTE: It is recommended that the knock-outs on the sides of the  

  connection box are used in conjunction with the cable gland [Fig.5]  
  as using the knock-out at the rear of the connection box will reduce the  
  weatherproof rating.

•  However, If feeding a wire(s) through the knock-out at the rear of the connection  
  box, this will need to be removed, the sealing grommet fi tted [Fig 6] and the  
  wire pushed through into the connection box BEFORE it is secured to the wall. 

•  If feeding a wire(s) through the side knock-outs, it is easiest to fi t the cable  
  gland to the connection box  [Fig.5]BEFORE securing it to the wall, and wires  
  should enter the connection box from the sides or underneath, not from the top.

•  Use the connection box Fixing Holes [Fig.7] to mark the 4 drill holes required to  
  secure the box to the wall (and mark the cable outlet location if required). Drill  
  the wall and screw the connection box onto the wall using the screws and wall  
  plugs provided.  

•  When the Connection Box has been screwed onto the wall, covers (provided)  
  should be fi tted over the screws to prevent water entering the Connection Box  
  through the screw holes. 

•  Once the wire(s) has been fed through the Sealing Gland, the nut on the gland  
  should be gently tightened up against the gland body [Fig. 8] to ensure the  
  wire(s) is secured in place and no water can get though into the connection box. 

3.2.1 OPTION 1: ATTACHING MIGHTYLIGHT VIA THE CONNECTION BOX 

Fig.8

Fig.7

Fig.5

Fig.6

Fixing Holes

Landscape

Portrait

Fig.4

Reviews: