TECHNICAL SPECIFICATIONS OF PRODUCT
HK7224K
Electromechanical gearmotor for automations of gates and
automatic doors with DC motor, epicyclical gear reducer and
mechanical release.
HK7024K
Electromechanical gearmotor for automations of gates and
automatic doors with DC motor, epicyclical gear reducer and
mechanical release. Built-in control unit and OXI radio receiver.
Type
Maximum torque
500 Nm
Nominal torque
120 Nm
Speed under no load
2.25 RPM
Speed at nominal torque
2.00 RPM
Maximum cycle frequency
40 cycles/hour
Maximum continuous cycle time
approx. 7 minutes
Application limits
the product can be used on gates with leaf weights up to 330 kg for lengths up to 1.8m or 200 kg
for lengths up to 3.5m (see graph 1)
Lifetime
estimated between 150,000 cycles and 500,000 cycles, according to the conditions stated in table 13 and graph 3
Assembly
Vertical, with dedicated fixing plate
Operating temperature
from -20°C to +50°C (at low temperatures, gearmotor efficiency is reduced)
se in acid, saline or
potentially explosive
NO
atmospheres
Protection rating
IP 54 (with container intact)
Dimensions (mm)
210 x 290 x 320 h
Weight (kg)
10.5 Kg;
9.5 Kg
Notes
:
(1)
- Function can be activated with Oview programmer.
[*]
- The outputs Flashing Light, Electric lock and Gate Open Indicator can be programmed with other functions (see “TABLE 3 – Level 1 functions”; or via the Oview programmer; see
chapter 8.3). The electrical specifications of the output are adapted to the type of selected function: • flashing light function: lamp 12 Vdc, max. 21 W; • electric lock function: 12 Vac
max. 15 VA; • other outputs (all types): 1 lamp or relay 24Vdc (-30 to +50%), max. 4 W.
Power supply
230 Vac (120 Vac for version
HK7024K/V1
)
24 Vdc (±10%)
±10%; 50/60 Hz
Backup power supply
Provision for buffer battery PS124
Solar power
provision for SYKCE kit
Maximum absorbed power
300 W
140 W
Maximum absorbed current
1,5 A (3 A for version
HK7024K/V1
)
6 A for a maximum interval of 2 s
Absorbed power with
“All – Standby (1)” function
when powered by PS124
less than 100 mW
or SYKCE kit (including
OXI receiver)
Flashing light output [*]
one LUCYB flashing light (12 V, 21 W bulb)
Electric lock output [*]
one 12 Vac electric lock (max 15 VA)
Gate open indicator output [*]
one 24 V lamp (max. 4 W) (the output voltage
may vary between -30 and +50%, the output can
also control small relays)
BLUEBUS output
one output with load of maximum 15 Bluebus
units (max. 6 pairs of MOFB or MOFOB photocells plus
2 pairs of MOFB or MOFOB photocells routed
as opening devices plus max. 4 MOMB
or MOTB control devices)
STOP input
for normally closed contacts, normally open
contacts or contacts with constant 8,2 k
Ω
resistance;
selection of the type of contact is in self-learning
mode and a modification with respect to the memorised
status will generate a “STOP”
SS input
for normally open contacts (closure of the contact
generates a Step Step command)
Radio engage
SM connector for receivers in the families SMXI,
OXI and OXIFM
Radio AERIAL input
50
Ω
for cable type RG58 or similar
Programmable functions
8 ON-OFF type functions (Table 3) and
8 settable functions (Table 5)
Functions in self-learning
• Self-learning of devices connected to the BlueBus output.
• Self-learning of the type of device connected to the “STOP”
terminal (NO, NC contact or 8,2 k
Ω
resistance).
• Self-learning of the gate leaf travel and automatic
calculation of deceleration points and partial opening.
• Self-learning of operation with one or two motors
WARNINGS: •
All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modifi-
cations to products at any time when deemed necessary, maintaining the same intended use and functionality.
Summary of Contents for HK7024
Page 2: ......
Page 25: ...IX 1 2 3 4 320 mm 210 mm 290 mm ...
Page 27: ...XI 1 2 a b 3 9 5 OK OK b a 9 b a a b x 4 c a 4 1 2 3 4 90 90 10 7 6 8 ...
Page 28: ...XII 9 1 2 a b 3 10 5 b x 4 c a 4 8 b a 10 1 2 3 13 11 6 OK OK 7 ...
Page 29: ...XIII 1 2 90 3 90 12 A 90 2 1 3 12 B 4 OK 3 NO 2 NO 11 1 3 2 5 4 ...
Page 31: ...6 1 2 8 7 15 1 3 5 1 2 2 4 XV ...
Page 32: ...XVI 16 1 2 7 6 17 L1 OPEN STOP CLOSE L2 L3 L4 L5 L6 L7 L8 ...
Page 33: ...XVII 1 2 1 2 18 1 3 5 1 2 2 2 1 4 19 1 2 ...
Page 34: ...XVIII 1 2 20 1 4 1 2 3 2 ...