SPA
Page 15
»
Press
once.
The new temperature set value is programmed. After a few seconds,
the program jumps back to the standard display. The display again
indicates the active cabin temperature.
Concerning Parameter G2, also see Section “Steam Bath Parameters
(G0 - G9, G13)” .
4.1.2
Steam Bath Exhaust Fan (D1)
Automatic - Function
On the automatic setting, the fan operation is a function of the steam
bath temperature. The control switches on the steam bath fan when
the set temperature level is reached and switches it off again when the
temperature falls below the set value, minus the hysteresis for the
steam bath fan (Parameter G3).
Also see Parameters “Temperature Set Value” (G2) and “Hysteresis
Steam Bath Fan” (G3). The
automatic
setting is preset in the factory
and is indicated on the display by an
F
.
Näheres finden Sie im Kapitel „Dampfbad-Temperaturverlauf“
Note:
More details to be found in the graph, also see Section “Steam Bath -
Temperature Control”.
Continuous Operation (Continuous On) - Function
With this setting the steam bath fan operates continuously regardless
of the temperature in the steam bath. Set this mode by pressing the
key once after start-up.
The display now indicates
f
for continuous operation of the fan. If an
F
is shown in the 1st line of the display, the fan is being controlled.
4.1.3
Essence Delivery System - Function (D2)
Automatic
The
automatic
setting for the Parameter “Essence Injector” (D2) is
indicated by an
E
in the display; essence is injected according to the
programmed essence delivery interval (G5) and Injection Duration
(G4). The factory setting for the essence delivery interval is 5 minutes
and the setting for the essence injection duration is 2 seconds.
Delivery System Off
By pressing the
key once, the
Essence Injector
Parameter is set
continuously to
off
. This is indicated in the display by an
e
and results
in no essence delivery into the steam bath.
4.1.4
Light - Function
Light (on / off)
When taking the steam generator into operation, the factory setting
Steam Bath
45 °C
42 °C
Menu
Steam Bath
42 °C
Menu
Please note
Steam Bath
45 °C
°C
F
E l
Steam Bath
F
45 °C
°C
f
E l
Steam Bath
E
45 °C
°C F
E
l
Steam Bath
45 °C
°C F
e
l
Steam Bath
L
45 °C
°C F e
L