Safety Instructions 

 

The following symbols and terms are used throughout this manual and on the machine to alert the reader to 
safety issues and important information: 

 

Symbol 

Term 

Explanation 

 

WARNING 

Indicates a hazardous situation which, if the safety instructions are 
not followed, can lead to injuries of the operator or bystanders, light 
and/or moderate damage to the product or the environment. 

 

STRONG MAGNET 

Indicates the machine contains strong magnets. These can cause 
pacemakers to stop or cause electronic data to be damaged, for 
instance on information stored on access passes. 

 

PACEMAKER 

Indicates operators and maintenance crew wearing pacemakers 
should keep a minimal distance of 6 inch/ 15 cm. In this specific 
case operators may not use the machine as a backpack. 

 

BATTERIES 

Indicates a battery operated machine, batteries must be charged 
according to the instructions in the separate Class I Battery Charger 
user manual. Batteries must be disposed of according to your local 
laws and regulations. 

 
 
Read all instructions before using HYGENIQ FOGGER 
 

Cautions when using the machine: 

 

 
Do not operate the machine without reading and understanding the instructions. If the machine is operated 
incorrectly it can pose danger to the operator and others and will invalidate the manufactures warranty. 
 
Please understand the followings: 
 

 

A risk assessment for the works to be undertaken; 

 

MSDS Chemical Data sheet; 

 

Risk assessment for chemical use. 

 
 
Keep the machine body upright and securely fastened at all times while using HYGENIQ FOGGER, during 
preparation and transportation. 
 
Only use approved HYGENIQ Mist and batteries for safe use of the machine. Using other consumable items in 
the machine invalidates the warranty and will lead to damage of the internal parts of the machine and could 
possibly pose a risk to operator. 
 
Maintenance/service people and operators with pacemaker need to keep a distance to the integrated 
magnets in HYGENIQ FOGGER of 6 inch/15 cm when they are doing maintenance on and operating FOGGER. 
 
Make sure the operator has been fully trained before using the machine.  
 
Avoid spray directly on humans and animals. 
 
Ensure the machine is used in a dry environment, and don not allow water or any other liquid around the 
motor air inlet. 
 

 
 
 
 
 

Summary of Contents for E150004

Page 1: ...USER MANUAL HYGENIQ FOGGER Model HYGENIQ FOGGER1 0 Product code E150004 Date 17 09 2020 Version A HYGENIQ Lenteweg 15 7532 RV Enschede The Netherlands 31 0 53 428 28 60 info hygeniq com www hygeniq com ...

Page 2: ... air in seconds It also makes disinfecting surfaces much more effective when combined with the approved HYGENIQ Mist Due to the 24V Li ion battery and refillable tank you can keep disinfecting for as long as you wish Please read the user manual carefully and become familiar with the operation and maintenance procedures Store the manual in a safe place ...

Page 3: ...HYGENIQ FOGGER 3 Content PREFACE 2 Packing List 4 Safety Instructions 5 Product Description 6 Setup 9 Operation 11 Maintenance 133 ...

Page 4: ...OGGER 4 Packing List Accessory The battery charger kit is provided according to customer order requirement It may not be in the machine package Please contact the supplier 1 x Battery 1 x Charger 1 x Power cable ...

Page 5: ...nstructions before using HYGENIQ FOGGER Cautions when using the machine Do not operate the machine without reading and understanding the instructions If the machine is operated incorrectly it can pose danger to the operator and others and will invalidate the manufactures warranty Please understand the followings A risk assessment for the works to be undertaken MSDS Chemical Data sheet Risk assessm...

Page 6: ...HYGENIQ FOGGER 6 Product Description ...

Page 7: ...t 1 3KG Battery voltage DC24V Duration of battery above 50 minutes Charger input voltage AC100 250 Voltage Charging time 2 5 Hours Speed of spray 175 100ml minutes Hose length 1 2 meters Droplet size 20 150um Spray nozzles 0 3x3mm 0 5mm 0 8mm 1 0mm Machine power 450W Spray distance 5 6 meters Pump DC24V 5W 100ml minute Main body material LDPE Spray handle material Aluminum ...

Page 8: ...HYGENIQ FOGGER 8 ...

Page 9: ...ke off the liquid tank from the machine and place and secure it in a upright position Unscrew the cap off the liquid tank and pour the approved HYGENIQ Mist into the tank Insert the liquid tank back to the machine which should also be placed in an upright position 3 Insert the battery to the machine Open the door of battery housing and sliding one fully charged battery into the battery housing unt...

Page 10: ...le Select the appropriate nozzle for the application Nozzle size Droplet size Spray distance Duration 3 5L Appliccation 0 3mm 3x 20um 5 6m 35minutes indoor 0 5mm 30um 5 6m 30minutes indoor 0 8mm 40um 5 6m 25 30minutes indoor 1 0mm 60um 5 6m 20 25minutes outdoor ...

Page 11: ...tion 1 Place the machine body on the table and then place the spray nozzle on the lower hook 2 Place the machine on the back and adjust the straps and the belt to for an optimal comfortable operating position 3 Spraying steps ...

Page 12: ...ffect is that the particles get heavier and via laws of Gravity descend This way the descending layer of mist works as a membrane filtering all other unwanted particles such as microdust out This results in a completely antibacterial filtered and purified air composition in the room Specific risk points like door handles light switches and other manual touch points can be targeted directly to ensu...

Page 13: ...xceed 4 hours for each continuous use 4 Ensure the machine is always used upright and in a dry environment and do not allow water or any other liquid around the motor air inlet 5 Spray nozzles need to be stored in the small tool box together with the screw driver The tool box can be hooked on to the backpack harness spring hook 3 nozzles in the tool box and 1 in the spray handle 6 If there is any ...

Reviews: