Programming the operating mode ramp
In this operating mode a ramp, devided in four stages, can be defined.
The values shown in above dialog results in this ramp:
Range A: Rising edge from
start value A
to
end value A
in time
duration A
.
Range B: Level B with
value B
and the dwell time
duration B
Range C: Falling edge from
start value C
to
end value C
in time
duration C
Range D: Level D with
value D
and the dwell time
duration D
Range
Starting value
Final value
Duration
A
10%...100%
10%...100%
0,01…10s
B
10%...100%
10%...100%
0,01…99,99s
C
10%...100%
10%...100%
0…99,99s
D
10%...100%
10%...100%
0…99,99s
After range "D" has expired, the proportional valve is set to 0V or 0%.
In cyclic mode, the system jumps to the start value "A" after range D. A maximum of 9999 cycles can be run.
Highlight the setting values of the curve, press and
enter the desired value and confirm with
.
Save and exit the setting with F5 .