![Hydronix Hydro-Probe XT User Manual Download Page 63](http://html.mh-extra.com/html/hydronix/hydro-probe-xt/hydro-probe-xt_user-manual_2192332063.webp)
Hydro-Probe XT User Guide HD0538 Rev: 1.6.0 63
Appendix A
Default parameters
The complete set of default parameters are listed in Engineering Note EN0071, available for
download from www.hydronix.com
1 Default Parameters
1.1
Firmware version HS0089
Parameter
HPXT Default
Output type
0-20mA (0-10V)
Output variable 1
Filtered Unscaled
Output variable 2
Material Temp
High %
20.00
Low %
00.00
Input Use 1
Avg. / Hold
Input/output Use 2
Unused
Unscaled Type
Mode V
Unscaled 2 Type
Mode E
Smoothing time
1.0
Slew rate +
Light
Slew rate -
Light
Digital Signal Processing
Unused
Material calibration
Moisture
A
0.0000
B
0.2857
C
-4.0000
SSD
0.00
Average hold delay
0.5 sec
High limit (m%)
30.00
Low limit (m%)
0.00
High limit (us)
100.00
Low limit (us)
0.00
Freq. Co
Ampl. Co
Electronics temp. coeff
0.0059
0.0637
Resonator temp. coeff
Set by test
Set by test
Material temp. coeff
0.00000
0.00000
Summary of Contents for Hydro-Probe XT
Page 4: ...4 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 6: ...6 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 8: ...8 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 10: ...10 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 14: ...Chapter 1 Introduction 14 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 42: ...Chapter 4 Configuration 42 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 58: ...Chapter 7 Sensor diagnostics 58 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 60: ...Chapter 8 Technical specification 60 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 66: ...Appendix B Document Cross Reference 66 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...