![Hydronix Hydro-Probe XT User Manual Download Page 19](http://html.mh-extra.com/html/hydronix/hydro-probe-xt/hydro-probe-xt_user-manual_2192332019.webp)
Hydro-Probe XT User Guide HD0538 Rev: 1.6.0 19
2.3
Conveyor belt mounting
The sensor should be secured to a suitable fixing bar using a Flanged Mounting Sleeve and a
Clamp Ring.
•
Allow a 25mm gap between the sensor and the conveyor belt
•
The minimum depth of material on the conveyor belt must be 150mm to cover the
ceramic faceplate.
The sensor faceplate must always be covered in material.
•
To improve the flow characteristics and level of material on the belt, it may be beneficial
to fit diverters onto the conveyor, as shown below. This can build up the material to a
deeper level for good measurement.
•
To aid calibration, a manual switch may be fitted alongside the belt to switch the
average/hold digital input. This will enable the readings to be averaged over a period of
time whilst collecting samples and so giving a representative Unscaled reading for
calibration (See Chapter 3 for connection details).
Diverters may be used to channel the
material to increase depth
25mm
Flow
Direction
Clamp Ring and Flanged
Mounting Sleeve
>150mm
Figure 10: Mounting the Hydro-Probe XT on a conveyor belt
Summary of Contents for Hydro-Probe XT
Page 4: ...4 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 6: ...6 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 8: ...8 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 10: ...10 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 14: ...Chapter 1 Introduction 14 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 42: ...Chapter 4 Configuration 42 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 58: ...Chapter 7 Sensor diagnostics 58 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 60: ...Chapter 8 Technical specification 60 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 66: ...Appendix B Document Cross Reference 66 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...