Page 38
9.3.5 Reinstallation of the steam cyl-
inder
»
Place the cylinder vertically in cylin-
der base.
»
Reconnect the electrode cabling.
The colour of the respective connection cable
must match the colour of the respective elec-
trode hand nut.
»
Check all cabling screw terminals
and plugs for tight seating. Plugs
must sit on their respective contacts
as far as they will go.
»
Check electrode plugs for corro-
sion. Replace, if stained.
Risk of functional disruption!
Risk of material damage!
Loose cable connections may result in
increased transition resistance and contact
area overheating.
»
Reattach Super Flush solenoid hose
(if applicable) to steam cylinder bot-
tom stub.
»
Attach steam hose adapter to cylin-
der.
»
Affix the steam hose adapter with
the clip.
»
Follow the handling instructions in
the section
Leakage test.
Please note
NOTICE