NOTE! To the installer: Please make sure you providethis manual to the owner of the pumping equipment or tothe responsible party who maintains the system.
Pump Installation and Service Manual
SubmersibleSump Pump
W/D/V-A1
W-A1
V-A1
D-A1
Page 1: ...ller Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual Submersible Sump Pump W D V A1 W A1 V A1 D A1 ...
Page 2: ...ock This pump has not been investi gated for use in swimming pool areas General Information Pump Warning 2 Make sure float automatic models hangs free It should not come into contact with side or bottom of sump pit 3 Make sure sump is free of string cloth nails gravel etc before installing pump 4 Do not set pump directly on the bottom of sump if it is not solid Raise the pump by placing bricks or ...
Page 3: ...lications and prod uct information contact your HYDROMATIC distributor Your pump warranty is void If power cord has been cut If pump has been used to pump mud cement tar abrasives or chemicals If pump has been used for pumping of hot water above 120 F If pump has been dismantled by other than authorized Hydromatic service center or distributor W A1 D A1 V A1 ...
Page 4: ...pen take to authorized service center for check Pump runs but does not deliver water 1 Check valve may be installed backward Arrow on valve points in direction of flow 2 Discharge gate valve if used may be closed 3 Pump may be air locked Start and stop several times by plugging and unplugging cord Check vent hole in pump case for plugging HYDROMATIC pumps have a small air vent hole in the impeller...
Page 5: ... in pump base may be clogged Remove pump and clean out openings 2 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 3 Pump impeller may be partially clogged causing motor to run slow resulting in motor over load Clear impeller 4 Fuse size or circuit breaker is too small 5 Defective motor stator return to authorized Hydromatic service center for verification ...
Page 6: ...6 W A1 D A1 V A1 Typical Installation ...
Page 7: ...1 5 Diaphragm Switch 20 1 NOT 13869 510 5 Vertical Switch 10 1 SHOWN 13869 520 5 Vertical Switch 20 1 1 26230A000 Ring Handle 1 2 14077 000 1 Pipe Plug 1 3 Motor Housing 1 4 Stator Seal Plate Rotor Shaft Assembly 1 5 139 014 1 Seal Ring 1 6 14770 005 1 Pan Screw 5 6 7 8521 101 1 Bottom Plate 1 8 14770 002 1 Pan Screw 6 5 9 8520 002 1 Base 1 10 8498 003 1 Impeller 1 11 21607A001 Shaft Seal 1 12 147...
Page 8: ...r and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 S...