HL 22019

): The carbon filter reduces sediment and certain chemicals, such as 

chlorine and chloramines from the water. Depending on water use and the amount of impurities, 

this filter should be replaced a minimum of 2,500 gallons of purified water produced. 

 membrane (

HL 22045

): The functional life of the 

 membranes will vary 

based on feed water quality. Product water should be tested periodically to verify the membranes are 

performing properly. For most applications, the 

 membranes should be replaced every 6 

months to two years.

BE SURE TO CHANGE YOUR FILTERS BASED ON THE FILTER 

REPLACEMENT SCHEDULE!   

FILTER REPLACEMENT SCHEDULE

HL 22019

HL 22045

Filter

HydroLogic Part #

Replacement 

Schedule

HL 22019

2,500 gallons of

purified water

Dry Membrane 

600 GPD

HL 22045

6 months–2 years

Summary of Contents for EvolutionRo

Page 1: ...BUILT IN THE U S A BUILT IN THE U S A USER MANUAL...

Page 2: ...SCRIPTION TABLE OF CONTENTS The is a customized Reverse Osmosis water filter that is made in the USA This system is capable of reducing up to 95 of most contaminants This system is designed and built...

Page 3: ...g filter cartridges use the filter wrench to remove housing Do not use the wrench to tighten the housings Hand tighten the housings only Take care not to over tighten 6 Do not install where leakage or...

Page 4: ...life of the membranes will vary based on feed water quality Product water should be tested periodically to verify the membranes are performing properly For most applications the membranes should be r...

Page 5: ...te White Feed Fitting X1 6 Blue Product Water Fitting X1 7 Orange 1 1 Ratio Drain Fitting X1 8 Green 2 1 Ratio Drain Fitting X1 9 Lock Bar X1 10 Pressure Gauge w Tee Fitting X1 11 Support Leg Housing...

Page 6: ...OU MUST REMOVE MEMBRANES FIRST Afterwards go back to STEP 9 to install the two membranes IMPORTANT BEFORE YOU START To ensure optimal efficiency the carbon filter MUST BE FLUSHED FOR 10 MINUTES PRIOR...

Page 7: ...membrane Do not rock membrane back and forth to install Repeat this step for second membrane hose inlet fitting onto other end of tubing This fitting is compatible with garden hoses and hose bibs STE...

Page 8: ...luminum Al 3 97 98 Ammonium NH4 85 95 Arsenic As 90 95 Borate B4O2 2 30 50 Boron B 60 70 Bromide Br 93 96 Cadmium Cd2 93 97 Calcium Ca 2 95 98 Chloride Cl 92 98 Chromate CrO4 2 85 95 Copper Cu2 96 98...

Page 9: ...one of the industry s most reliable and highest performing membranes that deliver consistent performance and quality Advanced membrane technology and manufacturing processes allow these membranes to...

Page 10: ...urized before removing fittings then push in the collet evenly against the face of the fitting With the collet held in this position the tube can be removed by simply pulling You can use a collet rele...

Page 11: ...specified operating parameters listed on page 8 Do not operate unit if incoming pressure exceeds 80 psi or there is problem with water hammer or pressure spikes The manufacturer believes the informati...

Page 12: ...verse Osmosis technology Since RO water is almost pure H2O and has no ability to buffer pH the actual pH reading will not be accurate until you add minerals back Q Why are both the 1 1 and 2 1 Flow Re...

Page 13: ...Wall Mount Bracket HL 10057 Stainless steel heavy duty bracket to mount your system on the wall Drain Saddle HL 10055 The optional drain saddle is an alternative way to run your drain line OPTIONS Flo...

Page 14: ...FILTER REPLACEMENT LOG MEMBRANE DATE CARBON FILTER DATE...

Page 15: ...USER NOTES...

Page 16: ...370 Encinal Street Suite 150 Santa Cruz CA 95060 ph 888 426 5644 fax 831 336 9840 techsupport hydrologicsystems com hydrologicsystems com ACCREDITED BUSINESS...

Reviews: