MODEL OS-100

Outdoor Sensor Kit

for Model 3200-

Plus 

and

Model 3250-

Plus

Fuel Smart HydroStats

manufactured after 0/0/11

WARNING

Electrical shock hazard.

To prevent electrical shock, death or

equipment damage, disconnect power supply before

installing or servicing control. Only qualified personnel may install or service this control in
accordance with local codes and ordinances. Read instructions completely before proceeding.

CAUTION

To prevent serious

burns, boiler

should be thoroughly cooled before installing or
servicing control.

Kit Includes 

• Outdoor Reset Sensor with 9-foot cable

• Sensor mounting bracket with 2 screws and 1 wire clip

• Two spade connectors

• Knockout wire bushing

This document provides instructions for connecting the Hydrolevel Outdoor Sensor Kit to an installed

Fuel Smart HydroStat control. For information on installing the HydroStat control, please refer to the
installation instructions provided with the control or log onto www.hydrolevel.com.

Before installation, determine the 
proper location for the sensor

• Sensor should be mounted on the

northern outside wall of the house,
shielded from direct sunlight.

• Sensor should be installed high

enough off the ground to protect 
it from accidental damage or 
drifting snow.

• Sensor should be installed away 

from potential heat sources 
such as exhaust fans, windows, 
or doors.

WARNING

Frozen pipes/water damage.

Central heating systems are prone to shut down as a result of power or fuel outages, 

safety related fault conditions or equipment failure. Installation of freeze protection monitoring or other precautions

is recommended for unattended dwellings in climates subject to sustained below-freezing temperatures.

Summary of Contents for HydroStat OS-100

Page 1: ...ument provides instructions for connecting the Hydrolevel Outdoor Sensor Kit to an installed Fuel Smart HydroStat control For information on installing the HydroStat control please refer to the installation instructions provided with the control or log onto www hydrolevel com Before installation determine the proper location for the sensor Sensor should be mounted on the northern outside wall of t...

Page 2: ...two spade connectors provided NOTE To avoid interference with the sensor signal do not run the sensor cable close to any other wiring such as telephone cable power etc Locate the three quick connect posts on the HydroStat circuit board The sensor cable will plug into two of these terminals depending on the features to be used OUTDOOR RESET AND WARM WEATHER SHUTDOWN Attach the spade connectors to t...

Page 3: ...Smart HydroStat control to the Reset Ratio determined by the intersec tion of a and b above Example For a house located in Springfield MA Design Temperature of 0 F with baseboard heat that was sized for the house based on the 180 F baseboard rating the reset ratio is 1 50 220 1 50 1 50 1 50 1 50 1 75 1 75 1 75 2 00 2 00 2 25 2 50 2 50 2 50 2 50 2 50 2 50 2 50 2 50 215 1 25 1 50 1 50 1 50 1 50 1 75...

Page 4: ...display will toggle between boiler temperature 8 seconds and outdoor temperature 2 seconds If the sensor becomes damaged or disconnected the control will automatically revert back to the Thermal Targeting reset method The display will no longer toggle outdoor temperature RESET RATIO The Fuel Smart HydroStat control s Outdoor Reset feature uses a reset ratio method to control the boiler temperature...

Reviews: