5. Maintenance and Inspection
5.1. Maintenance
Check the water supply device and the release often. You should avoid the condition of no
water or air entering into system, as this will influence unit's performance and reliability.
You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the
dirty of clogged filter.
The area around the unit should be dry, clean and well ventilated. Clean the side heating exchanger regularly to
maintain good heat exchange as conserve energy.
The operation pressure of the refrigerant system should only be serviced by a certified technician.
Check the power supply and cable connection often. Should the unit begin to operate abnormally, switch it off
and contact the qualified technician.
Discharge all water in the water pump and water system ,so that freezing of the water in the pump or water
system does not occur. You should discharge the water at the bottom of water pump if the unit will not be used
for an extended period of time. You should check the unit thoroughly and fill the system with water fully before
using it for the first time after a prolonged period of no usage.
5.2. Trouble Shooting
Guide
Malfunction
LCD controller
Reason
Resolution
Water inlet temp. Sensor failure
PP1
The sensor is open or short circuit
Check or change the sensor
Water outlet temp. Sensor failure
PP2
The sensor is open or short circuit
Check or change the sensor
Coil sensor failure
PP3
The sensor is open or short circuit
Check or change the sensor
Ambient sensor failure
PP5
Check or change the sensor
Coil sensor failure
Temp. Differential between water-
in and water-out is too large
PP6
Water flow volume not enough,
water pressure difference is too
low
Check the water flow volume or
system obstruction
Anti freezing under cooling mode
PP7
Outlet water is too low
Check the water flow volume or
outlet water temp. Sensor
The first time freezing protection
in winter
PP7
Ambient or inlet water temp. is too
low
The second time freezing
protection in winter
PP7
Ambient or inlet water temp. is too
lower
High pressure protect
HP
The sensor is open or short circuit
Check trough the high pressure
switch and the gas system
pressure to judge whether the gas
loop is blocked or the freon is
suitable
Low pressure protect
LP
The sensor is open or short circuit
Check trough the high pressure
switch and the gas system
pressure to judge whether there is
leaking or the freon is not enough
Flow switch failure
Light
Water flow volume not enough,
water pressure difference is too
low
Check the water flow volume,
water pump and flow switch is
failure or not
3times water-in and water-out
temp. difference protection in 30
minutes
EE5
Water flow rate not enough
Check the water flow rate, or
water system is jammed or not
Defrosting
Defrost code
display
Communication failure
EE8
LED controller and the PCB
connection failure
Check the wire connection
Summary of Contents for Hydro-Pro+ Premium 22M
Page 2: ......
Page 12: ...9 ...
Page 24: ......
Page 25: ...code 20141120 0001 ...
Page 27: ......
Page 39: ...4 VERWENDUNG UND BETRIEB 11 Verdampfungstemp Umgebungstemp ...
Page 53: ......
Page 54: ...Code 20141120 0001 ...
Page 56: ......
Page 68: ...4 GEBRUIK EN BEDIENING 11 Verdampingstemp Omgevingstemp ...
Page 82: ......
Page 83: ...code 20141120 0001 ...
Page 85: ......
Page 89: ...Chauffage température de l air extérieur 15 C température de l entrée d eau 26 C ...
Page 98: ...3 INSTALLATION ET RACCORDEMENT 15 Temp d évaporation Temp ambiante ...
Page 114: ...6 ANNEXES 31 ...
Page 115: ...6 ANNEXES 32 code 20141120 0001 ...
Page 117: ......
Page 121: ...opakowaniu Ogrzewanie Temperatura powietrza na zewnątrz 15 C temperatura wody wlotowej 26 C ...
Page 129: ...3 INSTALACJA I PODŁĄCZENIE 14 Temperatura parowania Temperatura otoczenia ...
Page 144: ...6 DODATEK 29 ...
Page 145: ...6 DODATEK 30 kod 20141120 0001 ...