- 16 -
Troubleshooting Continued
Problem
Cause
Solution
Vacuum
Motor Not
Running
Building circuit breaker
tripped. Reset breaker or move
cord to other outlet
Building circuit breaker tripped. Reset breaker or
move cord to other outlet
Faulty power cord
Replace cord
Faulty switch or internal
wiring Check wiring & test
switch
Repair as needed *
Vacuum motor faulty
Replace vacuum motor
Loss of
Vacuum
Vacuum motor faulty
Replace vacuum motor
Vacuum motor gasket
damaged
Replace gasket
Recovery tank lid gasket
damaged
Replace lid assembly or gasket
Vacuum hose or tool clogged
Clean out vacuum hoses and tool
Vacuum hoses or cuffs leaking
Replace vacuum hoses, cuffs & connectors as
needed
Recovery tank full
Drain tank
Float shutoff filter clogged
Clean float shutoff filter
Float shutoff stuck
Repair or replace float shutoff
Recovery tank damaged
Replace recovery tank
Tool won't
spray - slow or
uneven spray
Jet clogged
Clean out or replace jet
Inline filter clogged
Clean out or replace filter if so equipped
Jet worn
Replace jet
Jet not aligned properly
Re-align jet
Tool valve faulty
Repair or replace valve
Quick connects or hoses
restricted
Clean out or replace quick connects and/or hoses
Pump not pumping
See Troubleshooting sections relating to solution
pump
Summary of Contents for O100
Page 12: ...12 Wiring Diagrams O200H O500H O1200 ...
Page 13: ...13 O3 200H O3 500 ...
Page 14: ...14 O100 ...
Page 17: ... 17 Parts List and Breakdown Olympus Sub Assemblies ...
Page 18: ... 18 Solution Tank Assembly ...
Page 20: ... 20 Waste Tank Assembly ...
Page 23: ... 23 Auto Pump Out Assembly ...
Page 25: ... 25 Base Assembly ...
Page 27: ... 27 Vacuum Assembly ...
Page 29: ... 29 Pump and Heater Assembly ...