11
Clean and inspect
hoses
x
Check tanks,
hoses, filters and
power cables for
any signs of
damage or wear
x
Clean waste tank
gate valve
x
x
Clean Pump inlet
filter
x
x
1.
Remove the filter screen from inside the solution tank
and clean as needed.
2.
Do not operate the machine without the pump inlet
filter in place.
3.
Replace filter, hose & barb as needed.
Storage Freeze
Protection
x
1.
In a separate container mix 1 pint of water with 1 pint
of automotive radiator anti-freeze. (Ethylene glycol
type).
2.
Mix well and pour into the solution tank.
3.
Connect the solution hose to the solution outlet female
quick connect and hold the tool over a bucket.
4.
Turn the solution pump switch to the ON position.
Spray the tool into the bucket until you see the
antifreeze solution coming out of the jet into the
bucket.
5.
Turn the solution pump off.
6.
Drain the remaining anti-freeze solution from the
solution tank and the machine is ready for storage.
To Return to Service:
Repeat steps above using clean water ONLY until anti-
freeze has been cleaned from the unit.