HydrINS 2 / HydrINS 2 Mini flow meter
User Manual
Page 41 / 79
8.5.1
Internal power supply using 3.6 VDC lithium batteries
1 – Create the following configuration:
Switch SW2:
Internal
Connector J15:
Connect 1-2 and 15-16
2 – Connect the battery pack in the upper compartment and close the cover of Display A.
Figure 29: Connection of the lithium battery
8.5.2
External power supply using 3.6 VDC lithium batteries
1 – Create the following configuration:
Switch SW2:
External
Connector J15:
Connect 1-2 and 15-16
2 – Connect the battery pack to the
+/- 3.6 V
positions of the POWER connector, observing the
polarities.
Figure 30: Position to use for an external 3.6 V power supply