HydrINS 2 / HydrINS 2 Mini flow meter
Installation Manual
Page 22 / 79
Figure 13: Valid positions of the HydrINS 2/HydrINS 2 Mini flow meter sensor for flow measurement
4.4
Typical installation of HydrINS 2 / HydrINS 2 Mini flow meters
Typical installations are as follows:
HydrINS 2: 1" insertion – drill 25 mm (0.98 inches) at least
HydrINS 2 Mini: two possibilities:
o
Either 1" insertion plus 1"-3/4" adapter – drill 25 mm (0.98 inches) minimum: this
can measure the inside diameter of pipes using diameter gauges marketed by
HYDREKA and adaptable to 1" tappings.
o
Or 3/4" insertion – drill 19 mm (0.75 inches) minimum: does not need an adapter.
The preparation of an insertion point compatible with HydrINS 2 or HydrINS 2 Mini is exactly the
same as for the preparation of a classic insertion point for the installation of a connection. No
additional accessories are required. After drilling the pipe, tighten the HydrINS 2 /HydrINS 2 Mini
probe to the ball valve.
Position at 1/8 diameter
Position at 1/2 diameter