Machines manufactured at Hydralok, Bristol, UK
Machine enquiries, sales, after sales service :
Interpump Hydraulics (UK) Ltd t/a IMM Hydraulics (UK) : Kidderminster
Page.12
DIE CHART
Die No Range (mm) Length
Ferrule Dia Max Die No Range (mm) Length
Ferrule dia Max
*06
06.0 - 07.9
40.00
18.00
*26
26.0 - 29.9
50.00
38.00
*08
08.0 - 09.9
40.00
20.00
28
28.0 - 33.9
50.00
40.00
*10
10.0 - 12.9
40.00
22.00
*30
30.0 - 33.9
60.00
42.00
*13
13.0 - 15.9
40.00
25.00
34
34.0 - 39.9
70.00
46.00
16
16.0 - 18.9
40.00
28.00
40
40.0 - 45.9
70.00
52.00
*19
19.0 - 21.9
40.00
31.00
*46
46.0 - 51.9
75.00
58.00
22
22.0 - 25.9
50.00
34.00
*52
52.0 - 57.9
75.00
64.00
*These dies not supplied as standard
MAINTENANCE AND SERVICE.
A monthly check on the oil level should be carried out, more often for machines in regular
use.
The sliding surfaces of the head must be regularly lubricated with a molybdenum disulphide
based spray. A light spray of the surfaces each day should be sufficient but for machines
operating continuously or in hot climates it may require more frequent applications.
At yearly intervals it is recommended to re-calibrate the swaging head. Calibration
instructions enclosed.
A full service and calibration service is available from the manufacturer or authorized
distributor.
CALIBRATION INSTRUCTIONS
1. Complete a swaging assembly within the range of an appropriate die set.
2. Measure the finished assembly and from that size subtract the die size.
3. Using the figure arrived at from (2), check the calibrator reading.
4. If the calibrator requires adjustment loosen the retaining screw (item 3, fig 3)
5. Retain the knob (item1, fig 3) and rotate the adjusting ring (item 4, fig 3) using the
retaining screw key as a lever.
6. When the correct figure is reached re-tighten the retaining screw.
7. Set the calibrator to a new setting and produce a swaged assembly.
8. Check the finished swage size. (If incorrect repeat the calibration operation)