Page.10 

 

QUICK CHANGE 

 

Inserting dies into the machine 

1.  Set calibrator to quick change setting 

2.  With the machine set on manual press the green, swage, button and close dies until 

they reach the required setting. The green swage light will come on when this 
setting has been reached. 

3.  Select required die set 

4.  Holding the quick-change tool with both hands, line up the tool with the required die 

set. Line up the tool so that the pins on the tool sit in the holes positioning holes of 
the die set. 

5.  Switch on quick change tool 
6.  Dies will now be attached to the tool 
7.  Pull dies out of their insert on the rack. 
8.  Insert dies into machine in a parallel motion (not at an angle), with a firm push 

movement so that they click into place over the ball bearings, and then switch the 
die tool off.  

9.  Replace die tool back into its holder. 
10. You are now ready to complete a swage.  

 

Note: Quick change tool must be removed from dies BEFORE dies are opened. 

 

Removing dies from the machine  

 

1.  Set calibrator to quick change setting 
2.  With the machine set on manual press the green, swage, button and close dies until 

they reach the required setting. The green swage light will come on when this setting 
has been reached. 

3.  Holding the quick-change tool with both hands, line up the tool with the required die 

set. Line up the tool so that the pins on the tool sit in the holes positioning holes of the 
die set. 

4.  Switch on quick-change tool; you should hear a firm click when the dies attach 

themselves to the tool.  

5.  Remove the dies from machine in a parallel motion (not at an angle) with a firm pull 

movement. The dies must slide back over the ball bearing in a parallel movement, 
sometimes it is useful to give them a wiggle before removing to loosen them from their 
position. 

6.  The dies will now be attached to the quick change tool 
7.  Replace the dies into the correct insert in the rack, and turn off the tool. 
8.  Replace tool into the tool holder for safekeeping. 

Summary of Contents for H25ECO-QC

Page 1: ...anufactured at Hydralok Bristol UK Machine enquiries sales after sales service Interpump Hydraulics UK Ltd t a IMM Hydraulics UK Kidderminster Tel 0 121 550 1115 sales immhydraulics co uk USER MANUAL...

Page 2: ...WARRANTY CONDITIONS 3 EC DECLARATION OF CONFORMITY 4 SAFETY REGULATIONS 5 TECHNICAL DIMENSIONAL DATA 6 HANDLING TRANSPORT 6 ELECTRICAL INSTALLATION 6 PRELIMINARY CHECKS 6 LIGHTING 6 ROUTINE MAINTENAN...

Page 3: ...th shipping charges pre paid We will return items machines with carriage forward We are unable to accept items machines returned to us unless carriage charges have been paid 4 This warranty covers the...

Page 4: ...at Hydralok Bristol UK Machine enquiries sales after sales service Interpump Hydraulics UK Ltd t a IMM Hydraulics UK Kidderminster Tel 0 121 550 1115 sales immhydraulics co uk Page 4 EC DECLARATION O...

Page 5: ...may cause injury Do not touch any moving parts 3 CAUTION It is absolutely essential that all working operations are carried out by one operator only 4 This manual must be provided for the machine oper...

Page 6: ...ctrical installation must be carried out by a qualified electrician Check that your electrical installation is compatible with the motor requirements and specification supplied with the swaging machin...

Page 7: ...immhydraulics co uk Page 7 ROUTINE MAINTENANCE Ensure that moving parts are always lightly greased Where applicable check periodically that the limit switches and emergency controls are in good workin...

Page 8: ...die set using the die chart and the manufacturers recommended finished swage size Fit the dies into the swaging head as illustrated in Fig 2 Set the calibration unit to the required setting To determ...

Page 9: ...spring back energy trapped and released by the rubber and metal after swaging make occur especially with very large hose and fitting assemblies Switch off machine when not in use using the latching em...

Page 10: ...the die tool off 9 Replace die tool back into its holder 10 You are now ready to complete a swage Note Quick change tool must be removed from dies BEFORE dies are opened Removing dies from the machine...

Page 11: ...es immhydraulics co uk Page 11 DIE FITTING INSTRUCTIONS Dies are inserted from the front of the swaging head The die holders have a T slot with a spring loaded ball bearing to retain the dies Ensure t...

Page 12: ...ted with a molybdenum disulphide based spray A light spray of the surfaces each day should be sufficient but for machines operating continuously or in hot climates it may require more frequent applica...

Page 13: ...r sales service Interpump Hydraulics UK Ltd t a IMM Hydraulics UK Kidderminster Tel 0 121 550 1115 sales immhydraulics co uk Page 13 SPARE PARTS Item Part Number Description 9 10 11 12 13 14 300 078 s...

Page 14: ...ufactured at Hydralok Bristol UK Machine enquiries sales after sales service Interpump Hydraulics UK Ltd t a IMM Hydraulics UK Kidderminster Tel 0 121 550 1115 sales immhydraulics co uk Page 14 ELECTR...

Reviews: