•  Numbers in parenthesis ( ) refer to parts shown on back page

The Hydra-Cell Vacuum Priming Kit allows for a convenient way of removing air from behind the diaphragms.  It is applicable 

to all Hydra-Cell pumps.
Hydraulic priming, a requirement after diaphragm replacement, is achieved by attaching the assembly to the pump housing 

through the oil cap and pulling a vacuum.
Priming can be accomplished while the pump is turned off, but remaining in place.

Hydra-Cell Vacuum Priming Kit

Part Number A03-130-1200

Instant Information: www.hydra-cell.com

     A03-130-9900 6/2013

After replacing Hydra-Cell Pump diaphragms or if the loss of 

hydraulic prime is suspected, use the priming assembly to 

perform the following steps:
1.  Ensure pump is off.

           Warning: Personal injury or pump damage can      

           occur if pump is not turned off.

2.  Remove Oil Cap from Hydra-Cell Pump
3.  Install Oil Cap (8) with Oil Bottle (6) on Hydra-Cell Pump 

reservoir.

4.  The Hand Vacuum Pump (1) has two positions: Vacuum and 

Pressure. Set hand pump to Vacuum position (arrow down). 

Operating Instructions

Oil Cap (8)

Oil Bottle (6)

Vacuum Position 

Hand Vacuum 

Pump (1)

 

Rotating

 Gauge

 

Hydra-Cell Pump

 

Reservoir

W0548

(Arrow Down) 

5.  Position the Rotating Gauge as convenient. Hand operate 

the pump (1) until 25 in. HG is indicated on the gauge.

Note: If the oil bottle (6) starts to fill up with oil, release 

the vacuum with the lever at the bottom of the hand pump 

and start over (some oil may need to be removed from 

the reservoir).

5.  Hold vacuum for 15 minutes.
6.  Release vacuum with the lever at the bottom of the pump.  
7.  Remove Oil Cap with Oil Bottle on Hydra-Cell Pump 

reservoir.

8.  Add oil as necessary.  
9.  Replace Oil Cap from Hydra-Cell Pump.
10. Clean the Hydra-Cell Vacuum Priming Kit after each use.