5
Direct connection
Download the AQAMAI App and follow the steps on your device screen.
The device’s
default password
is: 12345678
To restore the default factory settings hold down the LR/LF’s button for
10 seconds and then release it.
Remote connection
During set up there will be an option to select your home router and
connect the LR/LF to the router itself. This means that you do not need
to connect to the lights Wi-Fi from your control device’s Wi-Fi every time
you want to adjust them. This will enable you to receive push notifications
should maintenance be required.
The router will need to be within Wi-Fi range of the LR/LF for a strong and
stable connection. A close proximity of between 1- 4 meters line of sight
is recommended for best connection.
ACCLIMATISING CORAL AND PLANTS
Enable this function if new corals or plants that need to acclimatize to LED
lamps are added; or if the lamp is introduced to an aquarium that is already
active. Set the starting percentage and the number of weeks in which the
intensity of the LED channels will reach the maximum set value. Example:
acclimation weeks: 4, Initial percentage: 50% If you have a daytime point
with an intensity of 80% on day 1 the daytime point will have an intensity
of 40%. LR/LF will daily increase daytime point percentage until it reaches
the 100% of scheduled final value.
LED COLOURS CODE
-
White:
LR/LF is booting up and setting Wi-Fi parameters. Wait until
colour changes.
-
Green:
All ok in direct connection mode;
-
Purple:
All ok in remote connection mode;
-
Blinking white - 1 sec:
Demo mode. Press the LR/LF button for 2
seconds and release it to turn off LR/LF for 10 minutes. Press again
to start the LR/LF manually. After 10 minutes LR/LF will return to daily
schedule.
-
Blinking purple/green - 1 sec:
Connection issues. LR/LF is not
able to connect to the network. Check if your router is switched on and
operating. Check if the SSID and/or PASSWORD of your home network
have not changed. To perform a factory reset, hold the button down
on the light for 10 seconds and then release; the light will reset and
reboot; wait until colour changes, then try to connect it to your home
network.
-
Blinking red:
Thermal cool down. The main LEDs will remain off until
the temperature reduces. Ensure that the LR/LF has sufficient air flow
and clearance. If problem persists contact AQAMAI Customer Support.
-
Blinking blue/green:
Firmware update in progress. If this procedure
is not completed, disconnect the lamp from the power supply, wait 30
seconds and try again.
-
Blinking red/green:
Hardware issue. Contact AQAMAI Customer
Support.
TROUBLESHOOTING & TIPS
Power loss
In case of a power loss all settings will be saved to the units memory and
will resume when power is supplied. If the fixture is without power for
more than 10 days, the light may need to be clock synchronized through
the App. All other light settings will remain saved.
Fixture dims to half intensity
LR/LF will automatically dim to half the command intensity in the event that
the fixture is operated beyond its intended ambient temperature range.
Once the temperature has gone down, the fixture will attempt to go back
to the intended intensity. If the problem persists contact AQAMAI Customer
Support.
Light will not turn on
Check all cord connections on power supply. Make sure the LR/LF is
plugged into power. Make sure the power outlet is working properly. If the
problem persists contact AQAMAI Customer Support.
Is in conformity with the following standards
EN 60950-1:2006/A12:2011
EN 60335-1:2013
EN 62479:2013
EN 301489-17:2009
EN 50598-1:2015
EN 55014:2014+A1:2016
EN 61547:2009
EN 60529/A2:2014
EN 62471_:2010
EN 62031:2009+A1:2015
EN61000-3-3/A2:2009+61000-3-2:2015
EN 61547:2010
EN 62493:2015
The UE DoC and the Technical Construction File required by this Directive
is maintained at the corporate headquarters of Hydor Srl, Via Voiron 27,
36061 Bassano Del Grappa (VI) Italy
This device contains
WI-FI Module
FCC ID: 2AC7Z-ESPWROOM02
GUARANTEE
The device is guaranteed for a period of 24 months from the date of purchase,
against defects in material and/or workmanship. Our guarantee does not apply
to claims the cause of which is due to installation and operation faults, lack of
maintenance, misuse of the device, effects of frost, furring and lime deposits
or amateur repair attempts.
The consumable materials and parts subject to wear and tear, must be periodically
replaced for normal maintenance of the device, are not included in our
guarantee. In case of product returning, attach it together with the purchase
receipt recording the date of purchase.
EU - DISPOSAL INFORMATION
This symbol means that according to local laws and regulations your
product should be disposed of separately from household waste. When
this product reaches its end of life, take it to a collection point designated
by local authorities. Some collection points accept products for free. The
separate collection and recycling of your product at the time of disposal
will help preserve natural resources and ensure that it is recycled in a
manner that protects human health and the environment.
MAINTENANCE
Attention
Before any kind of intervention, ALWAYS disconnect electrical supply of the
LR/LF. Regular cleaning and maintenance will guarantee the light better
and longer performance.
CE DECLARATION OF CONFORMITY
Manufacturer:
Hydor Srl, Via Voiron 27, 36061 Bassano Del Grappa
(VI) Italy
We declare, under our sole responsibility, that the product:
Equipment:
LED Lighting
Model:
LRm - LRs - LFm - LFs
Is in accordance with the dispositions of directives
R&TTE 2014/53/UE
LVD 2014/35/UE
EMC 2014/30/UE
RoHS 2011/35/UE