Performing maintenance
equipment, the draining fluid can flow
down to the electric motor.
3. Remove the tensioning clamp on the filter
bowl cover by completely removing the
nut.
Remove the housing clamp.
4. Pull off the filter bowl cover carefully in an
upwards direction.
Turn it slightly clockwise. This ensures
that the filter element remains locked on
the cover.
Turn counterclockwise to detach
the element from the cover and the dirt
catch tray from the element.
5. Remove the dirt catch tray.
6. Remove the filter element from the filter
bowl cover.
Dispose of the old filter element according
to local regulations and guidelines.
VMU 1 ATEX II 2G IIC T4
en(us)
Page 45 / 68
BeWa VMU_1_ATEX-II2GIICT4_10000649233 en-us 2017-03-07.doc