5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
48 / 120
BeWa MFU-10P 4391553c en-us web
Fig. 17:
Adjusting the feet 44°⇨ 0°
To adjust both feet from 44° to 0°, proceed as follows:
4.
Fully unscrew both screws counterclockwise with an
Allen key.
5.
Rotate the foot ≈ 22° inwards so that the bores in the
foot can be seen in the other threaded hole at the 0°
position in the filter head.
6.
Rotate the two screws clockwise into the other threaded
holes (position 0°) and tighten them securely with a
3 Nm torque.
NOTICE! Ensure that the screws are located fully
inside the threaded holes. If the screws protrude out
of the threaded hole, the position has not been
chosen correctly. Select the right position using the
hole in the foot.
O
The adjustment of the feet from 44° to 0° is complete.