HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 5
BeWa MFU-10P 4391553c en-us web
47 / 120
Fig. 16:
Adjusting the feet 0°⇨ 44°
To adjust both feet from 0° to 44°, proceed as follows:
1.
Fully unscrew both screws counterclockwise with an
Allen key.
2.
Rotate the foot ≈ 22° outwards so that the bores in the
foot can be seen in the other threaded hole at the 22°
position in the filter head.
3.
Rotate the two screws clockwise into the other threaded
holes (position 22°) and tighten them securely with a
3 Nm torque.
NOTICE! Ensure that the screws are located fully
inside the threaded holes. If the screws protrude out
of the threaded hole, the position has not been
chosen correctly. Select the right position using the
hole in the foot.
O
The adjustment of the feet from 0° to 44° is completed.