Technical data
Hydraulic data
MCS13xx
MCS14xx
MCS15xx
Flow rate
0,4 … 8 l/min
2 … 40 l/min
10 … 200 l/min
Maximum operating pressure 20 bar / 290 psi 20 bar / 290 psi 20 bar / 290 psi
Fluid temperature range
-40 … 85°C /
-40 … 185°F
-40 … 85°C /
-40 … 185°F
-40 … 85°C /
-40 … 185°F
Diameter / sensor cross-
section
1/4“
1/2“
1“
General data
Ambient temperature
-40 … 70°C /
-40 … 170°F
-40 … 70°C /
-40 … 170°F
-40 … 70°C /
-40 … 170°F
Mechanical connection
SAE 3/4“
SAE 3/4“
SAE 4“ (4x
M16)
Protection class to DIN 40050 IP 67
IP 67
IP 67
Weight
~ 3.0 kg
~ 2.5 kg
~ 3.5 kg
Dimensions (L x W x H)
83 x 120 x 120
mm
83 x 120 x 120
mm
83 x 162 x 140
mm
Vibration
10 - 58 Hz
0.75 mm
(amplitude)
0.75 mm
(amplitude)
0.75 mm
(amplitude)
58 - 500 Hz
10 g
(acceleration)
10 g
(acceleration)
10 g
(acceleration)
Shock
40 g
40 g
40 g
Electrical data
Operation voltage
9 ... 36 V DC, residual ripple < 10%
Power consumption
5 W max.
Electrical data
2 configurable switching
outputs
(n-switching Power MOSFET,
normally open)
1 x Ferromagnetic (Fe) particles
1 x Non-ferromagnetic (nFe) particles
or
1 x Particle (Fe + nFe)
1 x Device Ready signal
Switching output loadable with maximum: 1.5 A; 40 V DC
RS485 interface
2 wire, half duplex