background image

 

 

 

 

MCS 
Metallic 
Contamination Sensor

 

 

 

 

Operation and Installation Guide 

English (translation of original instructions) 
 

 

Documentation no.: 3435427g 
Valid from hardware index B and  
firmware version V 1.30 up 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MCS 13 series

Page 1: ...MCS Metallic Contamination Sensor Operation and Installation Guide English translation of original instructions Documentation no 3435427g Valid from hardware index B and firmware version V 1 30 up ...

Page 2: ...Dieter Dipl Kfm Wolfgang Haering Documentation Representative Mr Günter Harge c o HYDAC International GmbH Industriegebiet 66280 Sulzbach Saar Telephone 49 0 6897 509 1511 Fax 49 0 6897 509 1394 E mail guenter harge hydac com HYDAC FILTER SYSTEMS GMBH All rights reserved No part of this work may be reproduced in any form print photocopy or by other means or processed duplicated or distributed usin...

Page 3: ...se Deviating from Intended Use 12 Qualifications of personnel target group 13 Transporting the sensor 14 Storing the sensor 14 Decoding the model code label 15 Checking the scope of delivery 16 Scope of delivery for MCS 13xx 16 Scope of delivery for MCS 14xx 17 Scope of delivery for MCS 15xx 18 Sensor features 19 Functional principle 19 Sensor dimensions 20 Dimensions for MCS 13xx 20 Dimensions fo...

Page 4: ... Connecting cable wires 40 Examples of connection 41 Connection operation voltage measurement voltage 42 Using switching output 1 42 Using switching output 2 42 Using switching output 1 and 2 43 Connection operation voltage measurement voltage 43 Using switching output 1 43 Using switching output 2 44 Using switching output 1 and 2 44 Using switching outputs 45 Switching output FE NFE factory sett...

Page 5: ...ogic at the switching output 58 SWT PLS Set pulse length at the switching output 58 CANCEL cancel without saving 58 SAVE Save changes 58 Error analysis remedy 59 Error status active high and active low 62 Error status 1 active low 62 Error status 1 active high 63 Error status 2 active low 63 Error status 2 active high 64 Error status Device Ready 64 Performing maintenance 65 Decommissioning the se...

Page 6: ... us Page 6 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Non ferromagnetic nFe 74 Certification 74 Basics of GL certification 75 Germanischer Lloyd Industrial Services GmbH renewable energies 75 Index 76 ...

Page 7: ...n our liability shall be limited to foreseeable damage Claims due to Product Liability shall remain unaffected Technical Support Contact our technical sales department if you have any questions on our product When contacting us please always include the model type designation serial no and part no of the product Fax 49 0 6897 509 9046 E mail filtersystems hydac com Modifications to the Product We ...

Page 8: ... which topic I am looking for Where can I find the information I m looking for The documentation has a table of contents at the beginning There I select the chapter I m looking for and the corresponding page number de HYDAC Filtertechnik GmbH BeWa 123456a de Seite x Produkt Kapitel 200x xx xx The documentation number with its index enables you to order another copy of the operating and maintenance...

Page 9: ...e Do not operate the unit unless all the safety devices are present Secure the hazardous areas which may arise between the unit and other equipment Maintain the unit inspection intervals prescribed by law Document the results in an inspection certificate and keep it until the next inspection Hazard symbols These symbols are listed for all safety information and instructions in these operating inst...

Page 10: ...injury if not avoided CAUTION CAUTION indicates a danger with a low risk and which can lead to minor injury if not avoided NOTICE NOTICE indicates a danger which will lead to damage to property if not avoided Structure of the safety information and instructions All warning instructions in this manual are highlighted with pictograms and signal words The pictogram and the signal word indicate the se...

Page 11: ...t monitoring of particulate contamination in hydraulic and lubrication systems Proper or designated use of the product extends to the following observing all instructions contained in the instruction manual only using with permissible media operating within permissible technical conditions such as operating pressure flow rate media and ambient temperature The sensor is only to be used with the fol...

Page 12: ...l not be considered intended use HYDAC Filter Systems GmbH will assume no liability for any damage resulting from such use The user alone shall assume any and all associated risk Improper use may result in hazards and or will damage the sensor Examples of improper use Operation with a non approved medium Operation under impermissible operating conditions Modifications to the sensor made by the use...

Page 13: ...are aware of potential hazards due to improper use Specialist personnel such persons with corresponding specialist training and several years work experience They are able to assess and perform the work assigned to them they are also able to recognize potential hazards Activity Person Knowledge Transport storage Forwarding agent Auxiliary personnel No specialist knowledge required Hydraulic electr...

Page 14: ...lug will not be subjected to any mechanical strain or impact NOTICE Unsafe transport The connection plug will be damaged Transport the sensor in its original packaging Secure the sensor during transport Storing the sensor Store the sensor in a clean dry place in the original packing if possible Do not remove the packing until you are ready to install the unit Storage temperature 40 80 C 40 176 F R...

Page 15: ...e MetallicContamination Sensor see the type label This is located on the top of the unit and contains the exact product description and the serial number Row Definition Description 1 Model Model according to model code for details see page 72 2 P N Part no 3 S N Serial no 4 Date Year week of production 5 Index Hardware index 6 Max INLET press Maximum operating pressure ...

Page 16: ...s the scope of delivery for each size Scope of delivery for MCS 13xx The MetallicContamination Sensor MCS 13xx comes packed and factory assembled Before commissioning the sensor please check no items are missing from the package The following items are supplied Qty Designation 1 MetallicContamination Sensor MCS 13xx 1 O ring 18 7 x 3 53 NBR 70 Shore 1 Operation and Installation Guide this document...

Page 17: ... 14xx The MetallicContamination Sensor MCS 14xx comes packed and factory assembled Before commissioning the sensor please check no items are missing from the package The following items are supplied Qty Designation 1 MetallicContamination Sensor MCS 14xx 1 O ring 25 x 3 53 NBR 70 Shore 1 Operation and Installation Guide this document ...

Page 18: ...ntamination Sensor MCS 15xx comes packed and factory assembled Before commissioning the sensor please check no items are missing from the package The following items are supplied Qty Designation 1 MetallicContamination Sensor MCS 15xx 1 O ring 47 22 x 3 53 NBR 70 Shore 1 O ring 110 72 x 3 53 NBR 70 Shore 1 Operation and Installation Guide this document ...

Page 19: ...for the total particles Fe and nFe and the second switching output is used as a device ready signal For this see also the chapter Using switching output In addition the MCS has serial communication interfaces with which connection to superordinate monitoring systems is possible The MCS is intended for incorporation in low pressure circuits and test benches Functional principle Within the sensor a ...

Page 20: ...0 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Sensor dimensions The dimensions for the available sizes vary The dimensions for each size can be found below Dimensions for MCS 13xx Flange image SAE 3 4 All dimensions in mm ...

Page 21: ...Sensor dimensions MCS en us Page 21 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 13xx with Ethernet module Flange image SAE 3 4 All dimensions in mm ...

Page 22: ...Sensor dimensions MCS en us Page 22 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 13xx with flange adapter set optional accessory All dimensions in mm ...

Page 23: ...Sensor dimensions MCS en us Page 23 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 14xx Flange image SAE 3 4 All dimensions in mm ...

Page 24: ...Sensor dimensions MCS en us Page 24 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 14xx with Ethernet Flange image SAE 3 4 All dimensions in mm ...

Page 25: ...Sensor dimensions MCS en us Page 25 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 14xx with flange adapter set optional accessory All dimensions in mm ...

Page 26: ...Sensor dimensions MCS en us Page 26 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 15xx Flange image SAE 4 All dimensions in mm ...

Page 27: ...Sensor dimensions MCS en us Page 27 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 15xx with Ethernet Flange image SAE 3 4 All dimensions in mm ...

Page 28: ...Sensor dimensions MCS en us Page 28 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Dimensions for MCS 15xx with flange adapter set optional accessory All dimensions in mm ...

Page 29: ...w through the sensor The direction of flow is indicated by an arrow on the housing When selecting the installation site take ambient factors like the temperature dust water etc into account The sensor is designed for IP67 according to DIN 40050 EN 60529 IEC 529 VDE 0470 The sensor offers various options for mechanical installation Below you can find the possible mechanical installations permitted ...

Page 30: ... V13x en 2014 07 16 doc 2014 07 16 Connecting MCS14xx via flange adapter set A flange adapter set is available from HYDAC as an accessory under p no 3588249 This flange adapter set makes it possible for you to connect the MCS directly to two pipes or hoses via the thread G1 2 ...

Page 31: ...nderside MCS en us Page 31 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Fastening sensor to underside Sensors manufactured in 2012 and following have 4 fixing holes on the underside Use these to secure the MCS ...

Page 32: ...g V13x en 2014 07 16 doc 2014 07 16 Fastening MCS 13xx MCS 14xx Below you can see the drilling template for fastening the MCS 13xx 14xx All dimensions in mm Fastening the MCS 15xx Below you can see the drilling template for fastening the MCS 13xx 14xx All dimensions in mm ...

Page 33: ...ngle fastening set An angle fastening set is available as an accessory HYDAC article no 3477243 Connecting MCS 15xx with pipe adapter set A pipe adapter set is available as an accessory HYDAC article no 3435426 This pipe adapter set makes it possible to connect the MCS directly to two pipes or hoses via the thread 42L per ISO8431 1 ...

Page 34: ... flange adapter set is available as an accessory HYDAC article no 3442518 With the flange adapter set SAE4 SAE1 1 you have the opportunity to mount the MCS between the filter unit and the pump The flange adapter plate offers three connections for the integration of more sensors Example installation in the filter cooling circuit between pump and partial flow filter ...

Page 35: ...00 3435427g V13x en 2014 07 16 doc 2014 07 16 Connecting MCS 15xx with 4 SAE as per ISO 6162 1 4x M16 Install the MCS with four screws M16 to a component unit The drilling template corresponds to the SAE 4 per ISO 6162 1 Example installing the MCS on an NF filter ...

Page 36: ...an arrow on the housing NOTICE Exceeding the permissible operating pressure The sensor will be destroyed Note the maximum operating pressure of 20 bar 290 psi Diagram flow rate differential pressure p and viscosity Observe the measured volumetric flow rate For the MCS14xx this is between 2 and 40 l min and for the MCS15xx between 10 and 200 l min For flow rates outside these limits a detection of ...

Page 37: ...r MCS en us Page 37 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 P mbar Q l min P mbar Q l min The diagram shows the resulting differential pressure p mbar as a function of the flow rate Q l min at different viscosities ...

Page 38: ...nt 1 Supply voltage 9 36 V DC 2 Switching output 2 normally open 3 GND for supply voltage 4 GND switching output 5 HSI HYDAC Sensor Interface 6 RS485 7 RS485 8 Switching output 1 normally open The two switching outputs are in each case a passive n switching power MOSFET The switching outputs are open without current There is contact between the plug housing and the housing ...

Page 39: ...h one connection plug 8 pole M12x1 according to DIN VDE 0627 and an open end The color coding of the HYDAC accessory cable ZBE42 xx is listed in the table below All dimensions in mm Pin Color Connection to 1 White Supply voltage 9 36 V DC 2 Brown Switching output 2 3 Green GND supply voltage 4 Yellow GND switching output 5 Gray HSI HYDAC Sensor Interface 6 Pink RS485 7 Blue RS485 8 Red Switching o...

Page 40: ...RS 485 Converter GND GND GND 1 7 6 5 4 3 2 Schirm Shield Blindage 8 R 1k R 1k Pullup Pullup UM2 UM1 Lead voltages UM1 and UM2 as well as the load resistances and bridges via a separate external terminal strip Note that the voltage U may be 40 V DC at most and the current I 1 5 A at most Use for the pull up resistance 1kΩ You can find more possible examples starting on page 41 Using several supply ...

Page 41: ...grounded or not sufficiently connected to the PE conductor Note that the voltage U may be 40 V DC at most and the current I 1 5 A at most Using several supply voltages makes it necessary to define the following terms for error analysis Designation Description Operation voltage Voltage for operating the MCS electronics coil system Measurement voltage Voltage UM1 2 at switching output 1 2 for supero...

Page 42: ...80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Connection operation voltage measurement voltage In the following examples a measurement voltage and operation voltage of 9 to 36 V DC are used Using switching output 1 Using switching output 2 ...

Page 43: ...MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Using switching output 1 and 2 Connection operation voltage measurement voltage In the following examples a measurement voltage of 10 V DC and an operation voltage of 24 V DC are used Using switching output 1 ...

Page 44: ...Electrical connection of sensor MCS en us Page 44 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Using switching output 2 Using switching output 1 and 2 ...

Page 45: ... among the following settings for the switching output Switching output FE NFE factory setting A signal for all ferromagnetic Fe particles is output at switching output 1 and a signal for all non ferromagnetic nFe particles at switching output 2 Particles Switching Output ferromagnetic Fe 1 non ferromagnetic nFe 2 Switching output ALL RDY A signal for all ferromagnetic Fe particles and all non fer...

Page 46: ...ration of the signal between 5 and 200 ms This value is factory set to 7 ms The signal gives no indication of the shape and size of the particles Note that after the sensor has been switched on or after voltage has returned a start up phase of 70 seconds is necessary before the first measurement can be made Example Operation 1 particle detected 0 V 0 U t 70 s UM1 2 t Example Operation no particle ...

Page 47: ...Using switching outputs MCS en us Page 47 80 BeWa MCS1000 3435427g V13x en 2014 07 16 doc 2014 07 16 Example Operation several particles detected 0 V 0 UM1 2 U t t t t ...

Page 48: ...f the signal t between 5 and 200 ms This value is factory set to 7 ms The signal gives no indication of the shape and size of the particles Note that after the sensor has been switched on or after voltage has returned a start up phase of 70 seconds is necessary before the first measurement can be made Example Operation 1 particle detected 0 V 0 UM1 2 U t 70 s t 3 s Example Operation no particle de...

Page 49: ...ted on the switching output S1 The signal indicating that the MCS is ready for use is emitted on the switching output S2 The signal is always emitted in the same way regardless of the switching logic active low or active high Note that after the sensor has been switched on and after voltage has returned after an interruption a start up phase of 70 seconds is necessary before the signal can be eval...

Page 50: ...e to set parameters save the MCS measurement data with a time stamp read off stored data via USB memory stick forward the online measurement data to a PC forward the switching outputs to a superordinate controller MCS 1000 SMU 1200 HMG 3000 USB Memorystick HSI Bus Switching Output 1 2 1 2 3 4 5 6 7 8 braun brown brun gelb yellow jaune rot red rouge RS 232 PC RS 232 RS 232 USB A 18 35 V DC CS I B 2...

Page 51: ... MCS with CSI D 5 Condition Sensor Interface With the CSI D 5 kit you have the opportunity to parameterize the MCS using a PC and to read off online and stored measurement data Connect the CSI D 5 kit HYDAC article no 3249563 in accordance with the following connection diagram USB A USB B PS2 PC CSI D 5 MCS 1000 ZBE 43 05 CSI D 5 Kit ...

Page 52: ...4 07 16 doc 2014 07 16 Connecting MCS to HMG 3000 You can use the HMG 3000 to set the parameters of the MCS Connect the HMG 3000 to the MCS in accordance with the following connection diagram MCS 1000 HMG 3000 8 ZBE 41 ZBE 30 xx PS1 5 8 You can find more details in the HMG 3000 operating instructions ...

Page 53: ...irred up by shaking or vibration and then got into the fluid stream For detailed evaluation of the measurement results it is necessary to know the following operating parameters of the system Is a constant variable or only temporarily existent fluid stream through the sensor present Example During the analysis of the particles occurring each day the actual operating duration of the system is to be...

Page 54: ...structure Power Up Menu MODE M2 S TIME Set value SEL COM HSI ADRESS HSI Set value DEFAULT CANCEL SAVE Measuring menu DSPLAY FE A FE B FE C NFE D NFE E NFE F CYC A CYC B CYC C CYC D CYC E CYC F STATUS FI TEMP C TEMP F SWT OUT M2 FE NFE ALL RDY SWT LOG M2 ACT HI ACT LOW SWT PLS Set value CANCEL SAVE ...

Page 55: ...er of particles within the time intervals can be seen from the parameter DSPLAY CYC Parameter 1 120 minutes Factory setting 60 SEL COM Set protocol Purpose Set transfer protocol to the superordinate system Function Adjustment not possible Parameter none Factory setting HSI ADRESS Set bus address Parameter A Z for the HSI bus Factory setting D DFAULT Reset to factory setting Function Reset to the f...

Page 56: ...mber of particles per variable that were counted within the current measurement time parameter S TIME The measuring time begins when the voltage is switched on or the power up menu is exited The value of the current interval is always displayed Parameter FE A ferromagnetic particles Fe Class A FE B ferromagnetic particles Fe Class B FE C ferromagnetic particles Fe Class C NFE D non ferromagnetic p...

Page 57: ...surement via sensor in the spool TEMP F Medium temperature in F indirect measurement via sensor in the spool Factory setting FE A The value of 1000 µm is shown on the display as 1k SWT OUT Set switching output Function You can find a detailed description on page 45 S1 Ferromagnetic Fe FE NFE S2 Non ferromagnetic nFe S1 ferromagnetic Fe and non ferromagnetic nFe Parameter ALL RDY S2 Device Ready Fa...

Page 58: ...witching output ACT HI active high Parameter ACT LOW active low Factory setting ACT LOW SWT PLS Set pulse length at the switching output Function Setting the pulse length of the switching outputs Parameter 5 200 milliseconds Factory setting 7 CANCEL cancel without saving Parameter none SAVE Save changes Parameter none ...

Page 59: ...nics coil system Measurement voltage Voltage UM1 2 at switching output 1 2 for superordinate controllers Signal value Measurement voltage on high Measurement voltage off low Remove the connection cable on the MCS for error analysis and check the socket on the connection cable according to the following steps Step Pin Pin Description 1 1 3 Check the operation voltage 2 2 4 Check the measurement vol...

Page 60: ...0 3435427g V13x en 2014 07 16 doc 2014 07 16 1 7 6 5 4 3 2 8 Schirm Shield Blindage 1 2 3 4 5 6 7 8 Schirm Shield Blindage weiss white blanc grün green vert rosa pink rose blau blue bleu grau grey gris braun brown brun gelb yellow jaune rot red rouge 1 2 3 ...

Page 61: ...w low ON ON Error on the MCS Contact HYDAC low ON ON The MCS has not detected any particle active high high ON ON Error on the MCS Contact HYDAC ON OFF Error in measurement voltage Reestablish the measurement voltage OFF ON The MCS is switched off error in operation voltage Reestablish the operation voltage OFF OFF The MCS is switched off error in operation voltage measurement voltage Reestablish ...

Page 62: ...the sensor 2 Check the measurement voltage UM1 2 to the sensor 3 Perform a reset Remove the connection cable of the MCS for 10 seconds Reconnect the connection cable to the MCS 4 If there is no change in the error status contact HYDAC Observe the starting phase of 70 seconds Error status 1 active low The signal at the switching output is permanently free of voltage The MCS has detected an error 0 ...

Page 63: ... ON or OFF Measurement voltage UM1 2 ON Error status 2 active low The signal at the switching output is permanently voltage carrying The MCS has not detected an error This error occurs also when operation voltage is switched off and measurement voltage is switched on Only a superordinate controller can differentiate between this error signal and normal operation without detection of a particle Eva...

Page 64: ... external measurement voltage is switched off Only a superordinate controller can differentiate between this error signal and normal operation without detection of a particle Evaluate the signal duration and the behavior of the two switching outputs S1 and S2 separately 0 V 0 U t UM1 2 Operation voltage ON Measurement voltage UM1 2 OFF Error status Device Ready In the Device Ready error status the...

Page 65: ...e Decommissioning the sensor To decommission the unit proceed as follows 1 Remove the electric plug 2 Depressurize the unit 3 Remove the connected hoses piping from the sensor 4 Remove the sensor Disposing of sensor packaging material Dispose of the packaging material in an environmentally friendly manner After removing the sensor and separating its various materials dispose of it in an environmen...

Page 66: ...The following spare parts and accessories are available for the sensor Designation Qty Part no MCS14xx flange adapter set SAE G 1 2 consisting of 1x SAE flange 1x O ring NBR 4x cheese head screw 1 3588249 MCS15xx pipe adapter set 42L consisting of 2x pipe adapter 42L 2x O ring NBR 8x cheese head screw 8x washer 8x snap ring 1 3435426 ...

Page 67: ...1 3442518 MCS15xx angle plate set consisting of 1x angle plate 4x cheese head screw 8x washer 4x snap ring 4x nut 1 3477243 O ring 18 7 x 3 53 NBR 70 Shore 1 3112091 O ring 18 7 x 3 53 FPM low temperature 70 Shore 1 6140581 O ring 25 x 3 53 NBR 70 Shore 1 601905 O ring 25 x 3 53 FPM low temperature 70 Shore 1 6140582 O ring 47 22 x 3 53 NBR 70 Shore 1 604815 O ring 47 22 x 3 53 FPM low temperature...

Page 68: ...cket plug male 8 pole M12x1 ZBE 43 05 1 3281240 Socket plug female with screw clamp 8 pole M12x1 ZBE 44 1 3281243 Connection cable Ethernet Length 5 m Patch Socket plug 4 pole M12x1 RJ45 plug ZBE 45 05 1 3346100 Connection cable Ethernet Length 10 m Patch Socket plug 4 pole M12x1 RJ45 plug ZBE 45 10 1 3346101 Connection cable Ethernet Length 5 m Patch Socket plug 4 pole M12x1 RJ45 plug ZBE 46 05 1...

Page 69: ... Class C Fe 150 µm 200 µm 500 µm Class D nFe 200 300 µm 300 450 µm 550 750 µm Class E nFe 300 400 µm 450 600 µm 750 1000 µm Class F nFe 400 µm 600 µm 1000 µm Calibrating the sensor The sensor does not require regular calibrating Customer Service Use the following shipping address for repairs HYDAC SERVICE GMBH Friedrichsthaler Straße 15a Werk 13 66540 Neunkirchen Heinitz Germany Telephone 49 0 689...

Page 70: ...F Diameter sensor cross section 1 4 1 2 1 General data Permitted ambient temperature range 40 70 C 40 170 F 40 70 C 40 170 F 40 70 C 40 170 F Wetted seal material FPM low temperature FPM low temperature FPM low temperature Mechanical connection SAE 3 4 SAE 3 4 SAE 4 4x M16 Protection class to DIN 40050 IP 67 IP 67 IP 67 Weight 3 0 kg 2 5 kg 3 5 kg Dimensions L x W x H 83 x 120 x 120 mm 83 x 120 x ...

Page 71: ...normally open 1x ferromagnetic Fe particles 1x non ferromagnetic nFe particles or 1x particles Fe nFe 1x device ready signal Switching output loadable with maximum 1 5 A 40 V DC RS485 interface 2 wire half duplex HSI interface 1 wire half duplex Ethernet 10Base T 100Base TX Detection limits MCS13xx MCS14xx MCS15xx Particle size Fe 70 µm 100 µm 200 µm Particle size nFe 200 µm 300 µm 550 µm Particle...

Page 72: ... 2x switching outputs RS485 Ethernet HSI TCP IP protocol Fluids 0 Mineral and synthetic oils particularly used in wind power industry Mechanical connection 1 Flange connection SAE 1 2 according to ISO 6162 1 only for MCS13xx 2 Flange connection SAE 3 4 according to ISO 6162 1 only for MCS14xx 5 Flange connection SAE 4 according to ISO 6162 1 only for MCS15xx Electrical connection 0 Male connection...

Page 73: ... product that is not coordinated with us in writing will cause this declaration to lose its validity Designation MetallicContamination Sensor Type MCS1000 Series Part no Serial no EMC Guideline 2004 108 EG EU directive on electromagnetic compatibility EN 61000 6 3 Electromagnetic compatibility immunity EN 61000 6 2 2009 08 28 Thorsten Trier Date Name CE authorized person Executive director Documen...

Page 74: ...lly weak Non ferromagnetic nFe Many metals used in the industry do not have the above mentioned ferromagnetic property Examples include aluminum alloys copper brass as well as austenitic steels like stainless steel Such metals are called non ferromagnetic they can be easily checked with a commercially available permanent magnet If there is no adhesion the metal is nFe Certification The Metallic Co...

Page 75: ...ufacture Calibration Quality planning Product documentation comprising data sheet and operating and maintenance instructions Proof of function for the MCS 1000 EMC test Retrofitting in GL certified plants Condition monitoring systems in wind power plants which have already been certified by GL do not lose their certification if the MCS 1000 is built into the system after certification as the compo...

Page 76: ...61 62 63 64 F Filter 7 12 FluMoS 68 G GND 38 39 H Hardware 15 HSI 19 38 39 54 55 71 72 I INLET 15 ISO 35 53 72 M MODE 54 55 O OFF 61 62 63 64 P Parameter 55 56 57 58 S SAE 20 21 23 24 26 27 35 66 67 70 72 Sensor 1 11 15 16 17 18 19 20 38 39 51 72 73 74 Serial no 15 73 Service 69 SWT OUT 54 57 T TEMP 54 57 Transport 13 14 U USB 50 ...

Page 77: ......

Page 78: ......

Page 79: ......

Page 80: ...et Postfach 1251 66280 Sulzbach Saar 66273 Sulzbach Saar Germany Germany Phone 49 0 6897 509 01 Central Fax 49 0 6897 509 9046 Technical Department Fax 49 0 6897 509 577 Sales Department Internet www hydac com E Mail filtersystems hydac com ...