5.3 Electrical installation
For the electrical installation, proceed as follows:
DANGER
Danger from electrical voltage
Danger of fatal injury
u
Work on the electric supply may only be carried out by a
properly trained, certified electrician.
u
Before carrying out any work, disconnect the power plug
or deenergize the unit.
ü
Compare the voltage and frequency specifications on
the type label with the specifications for the available
network.
ü
The switch box is fastened, for details, see
1.
Hook up the power supply according to the accompany-
ing wiring diagram.
2.
Connect the connection cable with connection socket to
the water sensor.
3.
Connect the connection cable to the solenoid valve.
O
The electrical installation is completed.