Control Panel Basic (SIMATIC PANEL)
FAM 25/45/60/75/95
en(us)
Page 73/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Operating mode - MANU
MENU1 -> MANUAL
F1
F2
F3
F4
OPERATOR
= Manual operation for operator
SERVICE
= Manual operation for HYDAC Service (password-protected)
MENU1
= Back to MENU1
Operating mode - MANU – OPERATOR (MANU1)
MENU1 -> MANUAL -> Operator
F1
F2
F3
F4
= return to the screen
"Selection manual operation"
Manual
operation
= Switching manual operation on/off
The OFF displayed below Manual operation indicates that
manual operation is switched off.
FP
= Switch filling pump On/Off
EP
= Switching evacuation pump On/Off
Activate manual mode by pressing the F1 key. Now the individual components can
be switched on and off. If you switch from automatic mode back to manual mode,
automatic mode will stop. The current status of the pumps is shown. When
automatic mode has stopped, the display in manual mode changes to ON.
The operating status of each component is visible on the display.
OPERA-
TOR
MENU1
SERVICE
Selection
Manual
oper
OFF
NEXT
OFF
OFF
Manual 1
Exit
Manual-
operation
FP
EP
Summary of Contents for FluidAqua Mobil FAM 25