Electrical Connection of the FAM
DANGER
Exposed electrical components in the switch
cabinet
Danger of fatal injury due to electric shock
►
Any work involving the electrical system may
only be done by a properly trained, certified
electrician.
The electrical connection of units without connection plugs to the power
supply module may only be performed by a technician with corresponding
knowledge and skills.
Make sure that the voltage and frequency specifications on the FAM type
label correspond to the existing mains voltage.
If a plug is present on the FAM or if a plug is mounted, then the FAM is to be
operated from a correspondingly fused socket.
In order to keep the keep the temperature increase of th electric motors
within the permissible limits, observe range A in EN/IEC 60034-1 (VDE 0530-
1) (±5% voltage or ±2% frequency deviation, curve shape, network
symmetry) in relation to the specified rated voltage, unless otherwise
indicated on the type label of the electric motor.