7.11 Cleaning the diffuser on the filter membrane
holder
Clean the diffuser on the filter membrane holder at least once a
week.
Fig. 36:
Cleaning the diffuser
1 Coupling
2 Hose connection
3 Diffuser
4 Upper part of the filter membrane holder
ü
The test liquid in the analysis chamber is extracted fully.
ü
Shut the ball valve on the filter membrane holder.
1. Open the coupling (1) and remove the diffuser (3).
2. Clean the diffuser (3) by blowing it out with compressed air.
3. Put the diffuser in the filter membrane holder and tighten the
coupling (1) by hand.
O
The cleaning of the diffuser on the filter membrane holder is
complete.