background image

 

 

 

 

 

FES 

Fluid Sampling Set 

 

 

 

Operating and Maintenance Instructions

 

English 
(translation of original instructions) 

 

 

 

 

 

Document No.: 3160266a

 

 

 

Summary of Contents for CS 2000 Series

Page 1: ...FES Fluid Sampling Set Operating and Maintenance Instructions English translation of original instructions Document No 3160266a ...

Page 2: ... every endeavor to ensure the accuracy of the contents of this document However errors cannot be ruled out Consequently we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors The content of the manual is checked regularly Any corrections required will be incorporated in future editions We welcome any suggestions for impr...

Page 3: ... 7 Please observe the instructions in this manual 7 Responsibility of the owner 7 Hazards Posed by Using the FES 8 Proper Designated Use 8 Informal Safety Precautions 8 Modifications on the FES 8 Cleaning the FES 8 Checking the scope of delivery 9 Fluid Sampling Set properties 10 Source of oil contamination 10 Oil contaminations influence the ageing of the oil 11 Sampling 12 Static sampling 12 Dyn...

Page 4: ... is always available Note that the information on the unit s engineering contained in the documentation was that available at the time of publication There may be deviations in technical details figures and dimensions as a result If you discover errors while reading the documentation or have additional comments or suggestions contact us at HYDAC Filtertechnik GmbH Division Service technology Filte...

Page 5: ...roduct e g purchasing additional options etc may mean that the information in the operating instructions is no longer applicable or adequate After modification or repair work that affects the safety of the product has been carried out on components the product may not be returned to operation until it has been checked and released by a HYDAC technician Please notify us immediately of any modificat...

Page 6: ... information I m looking for The documentation has a table of contents at the beginning There I select the chapter I m looking for and the corresponding page number de HYDAC Filtertechnik GmbH BeWa 123456a de Seite x Produkt Kapitel 200x xx xx Product Page number Edition date Document language Documentation no with index file name The documentation number with its index enables you to order anothe...

Page 7: ...property damage if safety precautions are not observed Please observe the instructions in this manual These operating instructions contain the key instructions for properly and safely operating the FES These operating instructions in general and the safety guidelines in particular are to be observed by all those who work with the FluidSampling Set In addition the accident prevention rules and regu...

Page 8: ...ny liability for any damage resulting from such use Informal Safety Precautions Always keep the operating instructions in the vicinity of the Fluid Sampling Set In addition to the manual the general and local regulations concerning accident prevention and protection of the environment should be available and observed Keep the safety and hazard symbols and warnings on the Fluid Sampling Set in a le...

Page 9: ... in transit before putting the FES into operation Item Qty Description 1 Hand vacuum pump with manometer 1 Aluminum adapter 1 Set of sample flasks 2 pieces 1 Spray bottle with removable nozzle 500 ml 1 Disposable membrane filter for spray bottle Packing unit 2 pieces 1 Plastic hose length 2 m 1 Telescope pen length 0 9 m 1 Cable strip 20 pcs 1 Dynamic sampling device 1 Minimess hose screw screw 1 ...

Page 10: ...o the particular physical state Solid Gaseous and liquid contamination Solid particles enter the hydraulic system because the unit is inadequately sealed through maintenance work or new oil for example Once present these particles produce new ones leading to a chain reaction of wear Gaseous contamination often results from leakage on the suction side of hydraulic pumps poor return flow of the medi...

Page 11: ...drocarbon molecules which reduces the oil s service life considerably This occurs especially quickly when several contaminants act on the oil at the same time Air Under normal conditions mineral oils always contain a certain percentage of dissolved air Unfavourable conditions e g a vacuum can change the dissolved state of the air This released air is responsible for the increased compressibility o...

Page 12: ...rent hose with the aluminium adapter 4 Open the reservoir by removing the reservoir sealing lock or the tank ventilation filter 5 Place the laboratory bottle for blank sampling up against the aluminium adapter 6 Guide the longer transparent hose of the manual vacuum pump into the fluid contained in the reservoir up to approximately half the filling height The transparent hose can also be fastened ...

Page 13: ...tles provided Make sure that there is no possibility of contamination in the area of the sealing lock Undo the seal on the sample bottle but do not remove it Set the sample bottle down in easy reach 4 Remove the protective cap from the sampling valve e g nipple and allow an amount of fluid that is at least twice the volumetric size of the sampling line to drain out into a container This is necessa...

Page 14: ...al for ensuring the quality of the analysis result of the oil samples For rinsing the laboratory bottles we recommend N heptane which should be decanted into the accompanying spray bottle with membrane filter for this purpose Disposing of the FES When decommissioning and or disposing of the FES adhere to local guidelines and regulations pertaining to occupational safety and environmental protectio...

Page 15: ...f sample flasks 2 pieces 309 352 1 Spray bottle with removable nozzle 500 ml 309 358 1 Disposable membrane filter for spray bottle Packing unit 2 pieces 309 371 1 Plastic hose length 2 m 309 374 1 Telescope length 0 9 m 309 342 1 Kable strip 20 pcs 627 500 1 Dynamic sampling device 309 348 1 Minimess hose screw screw 309 350 1 Minimess hose screw plug 309 351 1 Wide mouth bottle 500 ml 309 360 1 C...

Page 16: ...chnology Division Industriegebiet Postfach 1251 66280 Sulzbach Saar 66273 Sulzbach Saar Germany Germany Tel 49 0 6897 509 01 Fax 49 0 6897 509 846 Technical Department Fax 49 0 6897 509 577 Sales Department Internet www hydac com email filtersysteme hydac com ...