background image

mounting instructions                                                                        OLF-5-TAK tank connection kit

HYDAC Filtertechnik GmbH

page 9 of 9

2.3.7 

Mount ventilation filter

Mount ventilation filter on the
adapter with a new seal and the
correct screws.

Summary of Contents for 3039235

Page 1: ...C Filtertechnik GmbH page 1 of 9 _______________________________________________ Mounting instructions Off line filter tank connection kit OLF 5 TAK Tank connection kit 2 0 Art No 3039235 last update 12 99 ...

Page 2: ... liability We have used our best endeavours to ensure the accuracy of the contents of this document However errors cannot be ruled out Consequently we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors The content of the manual is checked regularly Any corrections required will be incorporated in subsequent editions We ...

Page 3: ...of 9 Content 1 Description 4 2 Mounting 6 2 1 DIMENSIONS AT THE ADAPTER 6 2 2 FLOW RATES 6 2 3 MOUNTING INSTRUCTIONS 7 2 3 1 Return pipe 7 2 3 2 Suction pipe 7 2 3 3 Ventilation filter 8 2 3 4 Seal 8 2 3 5 Adapter 8 2 3 6 Suction and return connection 8 2 3 7 Mount ventilation filter 9 ...

Page 4: ...ws M5 x 120 1 pce setscrew M5 x 8 1 pce return hose Ø 38 x 3 length 400 mm 45 bevelled 1 pce suction hose Ø 26 9 x 2 3 length 800 mm with G3 4 thread on one side at the free end 200 mm 90 offset suction line 1 pce straight screw fitting GE 22 L G 1 pce hose DIN 20066 DN 20 1 SN length 1250 mm 2 pcs ell bend 90 DIN 3942 22L 1 pce straight screw fitting GE 22 L G return line 2 pcs straight screw fit...

Page 5: ...mounting instructions OLF 5 TAK tank connection kit HYDAC Filtertechnik GmbH page 5 of 9 bypass filter unit ventilation suction hose return hose adapter ventilation filter R S ...

Page 6: ... suction hose G thread cut open on one side Dimension 26 9 x 2 3 DIN 2448 return hose DIN 2391 C 45 angle cut on one side Dimension 38 x 3 2 2 Flow rates flow rate l min viscosity mm s suction pressure bar return pessure bar 5 200 0 3 1 150 0 1 0 7 100 0 06 0 5 46 0 06 0 3 15 90 0 2 1 5 60 0 18 1 2 The values were calculated using the delivered hoses and screwed connections com pare ch 1 delivery ...

Page 7: ...reaches beneath the oil level in the tank Insert the return pipe into the adapter and fix it with the setscrew It is possible to additionally glue it in place 2 3 2 Suction pipe has to be fitted as far from the re turn pipe as possible see drawing in ch 1 Screw suction pipe into the adapter and glue it in place If the suction pipe is too short add an oil resistant hose using a pipe clamp to connec...

Page 8: ...on filter of hydraulic unit 2 3 4 Seal Remove seal from tank cover and clean surface Put new seal in place 2 3 5 Adapter has to be mounted on oil tank with fillister head machine screws M5 x 120 and seal 2 3 6 Suction and return connection Connect S to the suction connec tion and R to the return connec tion of the bypass filter unit ...

Page 9: ...mounting instructions OLF 5 TAK tank connection kit HYDAC Filtertechnik GmbH page 9 of 9 2 3 7 Mount ventilation filter Mount ventilation filter on the adapter with a new seal and the correct screws ...

Reviews: