MRF 3
Performing maintenance
Performing maintenance
WARNING
Hydraulic systems are under pressure
Bodily injury
►
The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
The MRF is standardly equipped with an electric differential pressure gauge
(red/green) which shows when an element needs to be replaced.
The MRF can be optionally equipped with an electric back-pressure indicator or
differential pressure gauge.
Replacing the filter elements
To change the filter elements, proceed as follows:
1.
Switch the pump off and close the shut-off
valves at the inlet and outlet.
2.
Depressurize the filter housing.
Carefully unscrew the air bleed screw in the
cover counterclockwise using a 10 mm Allen
wrench.
The air bleed screw has ventilation slots.
3.
Open the drain valve on the dirt side and collect
the escaping fluid with a suitable container.
Once no more fluid escapes, close the drain
valve.